Graco 332564B Error Codes, Purge Errors Code Type Description Problem Cause Solution

Models: 332564B

1 104
Download 104 pages 58.79 Kb
Page 89
Image 89

System Errors

Error Codes

NOTE: When an error occurs be sure to determine the code before resetting it. If you forget which code occurred, use the Errors Screen, page 65 to view the last 200 errors, with date, time, and description.

Purge Errors

Code

Type

 

Description

Problem

Cause

Solution

F7P1

Alarm

 

Air Flow

The air flow switch is

Air flow switch is stuck

Clean or replace switch.

 

 

 

Switch On

indicating unexpected

in flow position.

 

 

 

 

 

atomizing air flow.

Leak downstream in air

Check for leaks and

 

 

 

 

 

 

 

 

 

 

line or fitting.

tighten fittings.

 

 

 

 

 

Air supply pressure

Eliminate pressure

 

 

 

 

 

fluctuation.

fluctuations.

SPD1

Alarm

 

Gun Purge

The system timed out

Solvent flow switch not

Replace switch.

 

 

 

Incomplete

without reaching the

working.

 

 

 

 

 

user-specified volume

Solvent flow is too low

Increase solvent

 

 

 

 

of solvent for a purge.

 

 

 

 

to actuate the solvent

pressure to drive a

 

 

 

 

 

 

 

 

 

 

switch.

high purge flow rate

 

 

 

 

 

Gun is not triggered.

Operator must continue

 

 

 

 

 

 

flushing for configured

 

 

 

 

 

 

time, until the booth

 

 

 

 

 

 

control indicates purge

 

 

 

 

 

 

is completed.

 

 

 

 

 

Mix manifold was not

Set manifold to flush

 

 

 

 

 

set to flush position,

position.

 

 

 

 

 

blocking solvent flow to

 

 

 

 

 

 

the spray gun.

 

Mix Errors

 

 

 

 

 

 

 

 

 

 

 

 

Code

Type

 

Description

Problem

Cause

Solution

 

 

 

 

 

 

 

F7S1

Alarm

 

Flow

The solvent flow

Solvent flow switch is

Clean or replace switch.

 

 

 

Detected

switch is indicating

stuck in flow position.

 

 

 

 

Solvent

unexpected solvent

There is a leak through

Check for leaks and

 

 

 

Gun

flow.

 

 

 

the solvent cutoff valve.

repair valve.

 

 

 

 

 

 

 

 

 

 

 

 

QPD1

Alarm,

 

Potlife

Potlife time has expired

Purge process was not

Make sure purge

 

then

 

Expired

before the system has

completed.

process is completed.

 

Devia-

 

 

moved the required

Solvent supply shut off

Verify solvent supply

 

tion

 

 

amount of material

 

 

 

or empty.

is available and on,

 

 

 

 

(potlife volume) through

 

 

 

 

the mixed material line.

 

supply valves are open.

 

 

 

 

 

 

 

 

 

 

 

 

 

SND1

Alarm

 

Mix Fill

The system timed out

Mix manifold not set to

Set manifold to spray.

 

 

 

Incomplete

before the mix fill cycle

spray position.

 

 

 

 

 

loaded the gun with

Spray gun was not

Allow flow through gun

 

 

 

 

mixed material.

 

 

 

 

triggered.

during fill process until

 

 

 

 

 

 

 

 

 

 

 

the fill complete LED

 

 

 

 

 

 

stops flashing.

 

 

 

 

 

Restrictions in mixer,

Fix restrictions.

 

 

 

 

 

manifold, or spray gun.

 

332564B

89