Graco 332564B important safety instructions Cagx, Cdc#, Cddx

Models: 332564B

1 104
Download 104 pages 58.79 Kb
Page 96
Image 96

System Errors

Code

Type

Description

Problem

Cause

Solution

 

 

 

 

 

 

CAGX

Alarm

Comm. Error

System does not

 

 

 

 

Gateway

detect a CGM that

 

 

 

 

 

was registered as

 

 

 

 

 

being connected at

 

 

 

 

 

power up.

 

 

CDC#

Alarm

Duplicate

System detects two or

More than one Color

Check the system

 

 

Color Change

more identical Color

Change Module with

and remove the extra

 

 

#

Change Modules.

the same address

color change module.

 

 

 

 

is connected in the

 

 

 

 

 

system .

 

CDDX

Alarm

Duplicate

System sees two

More than one EFCM

Check the system

 

 

Fluid Module

or more identical

is connected in the

and remove the extra

 

 

 

Enhanced Fluid

system.

EFCM.

 

 

 

Control Modules

 

 

 

 

 

EFCM).

 

 

96

332564B

Page 96
Image 96
Graco 332564B important safety instructions Cagx, Cdc#, Cddx