Operation Using a Programmable Logic Controller (PLC)

Network Output Data Map (Read Only)

Network

Modbus

Parameter Name

Data Type

Units

Range

Output ID

Register

 

 

 

 

 

 

 

 

 

 

 

00

40100

Current System

uint32

NONE

1 = Pump Off

 

 

Mode

 

 

2 = Recipe Change

 

 

 

 

 

 

 

 

 

 

3 = Recipe Change:

 

 

 

 

 

Purge A

 

 

 

 

 

4 = Recipe Change:

 

 

 

 

 

Purge B

 

 

 

 

 

5 = Recipe Change: Fill

 

 

 

 

 

6

= Mix Fill

 

 

 

 

 

7

= Mix

 

 

 

 

 

8

= Mix Idle

 

 

 

 

 

9

= Purge A

 

 

 

 

 

10 = Purge B

 

 

 

 

 

11 = Standby: Mix Ready

 

 

 

 

 

12 = Standby: Fill Ready

 

 

 

 

 

13 = Standby: Mix Not

 

 

 

 

 

Ready

 

 

 

 

 

14 = Standby: Alarm

 

 

 

 

 

 

01

40102

Pump 1 Status

uint32

NONE

0 = Off

 

 

 

 

 

1

= Standby

 

 

 

 

 

2

= Busy

 

 

 

 

 

3

= Flushing

 

 

 

 

 

4

= Priming

 

 

 

 

 

 

02

40104

Pump 2 Status

uint32

NONE

0 = Off

 

 

 

 

 

1

= Standby

 

 

 

 

 

2

= Busy

 

 

 

 

 

3

= Flushing

 

 

 

 

 

4

= Priming

 

 

 

 

 

 

03

40106

Pump 3 Status

uint32

NONE

0 = Off

 

 

 

 

 

1

= Standby

 

 

 

 

 

2

= Busy

 

 

 

 

 

3

= Flushing

 

 

 

 

 

4

= Priming

 

 

 

 

 

 

 