Prime and Fill the System

NOTE: See Run Mode Screens, page 58, for further screen information, if needed.

NOTE: You must prime the input lines to the pumps or the inputs to the color change valves before priming the pump and filling the entire system.

1.If using an electrostatic gun, shut off the electrostatics before filling the lines.

2.Adjust the main air pressure. To ensure proper operation, set the main air pressure as close to 100 psi (0.7 MPa, 7.0 bar) as possible. Do not use less than 85 psi (0.6 MPa, 6.0 bar).

3.If this is the first time starting up the system, or if lines may contain air, purge as instructed under

. Flush the System, page 23 The equipment was tested with lightweight oil, which should be flushed out to avoid contaminating your material.

4.If the system is powered down, press on the ADM. Make sure that the system is in Standby mode.

5.Verify that the recipes and the flush sequences are programmed correctly by checking

the Recipe Screen, page 72 and the Flush Screen, page 73.

6.Enable the manual override on System Screen 5.

7.Go to the Fill Screen, page 63.

8.Select the desired color to load. Press the Prime

Pump key . The color will load the pump through the color stack and out the outlet stack dump valve.

NOTE: In a single color system, skip step 7 and prime the pump out to the gun.

9.Press the Fill Line key to run color out to the remote mix manifold. The pump will run until

you press the Stop key to stop the pump.

10.Trigger the gun into a grounded reservoir or purge receptacle until the line is full, then press

the Stop key .

11.Repeat for all material lines.