System Errors

Code

Type

Description

Problem

Cause

Solution

 

 

 

 

 

 

F1F#

Alarm

Flow Low

There has been no flow

There is a restriction on

Make sure there are no

 

 

Fill Pump #

or low flow during a

the outlet side of the

restrictions in the color

 

 

 

pump fill operation.

pump or color stack.

stack and that the dump

 

 

 

 

 

valve is actuating.

 

 

 

 

Thick viscosity paint

Increase non-mix

 

 

 

 

requires more pressure

pressure if necessary

 

 

 

 

to pump.

to create flow during

 

 

 

 

 

the fill function.

 

 

 

 

The pumps do not

Increase non-mix

 

 

 

 

have to move for the

pressure if necessary

 

 

 

 

system to build enough

to create flow during

 

 

 

 

pressure to meet the

the fill function.

 

 

 

 

setpoint.

 

F1S#

Alarm

Flow Low

There has been no flow

Restriction in the outlet

Make sure there are

 

 

Purge Pump

or low flow during a

side of the pump or

no restrictions in the

 

 

#

pump purge operation.

color stack resulting in

system. Increase

 

 

 

 

the solvent flow being

non-mix pressure if

 

 

 

 

too low.

necessary to create

 

 

 

 

 

flow during the purge

 

 

 

 

 

function.

F7D#

Alarm

Flow

The pump flow

There is a leak in the

Verify there are no

 

 

Detected

exceeded 20 cc/min

system or the gun was

leaks in the system.

 

 

Pump #

flow coming into Idle

open when the system

Make sure the air flow

 

 

 

mode.

went into Idle mode.

switch is actuating

 

 

 

 

 

properly. Do not

 

 

 

 

 

trigger the gun without

 

 

 

 

 

atomizing air.

F8D1

Alarm

Flow Not

No flow while mixing.

Restriction in the outlet

Make sure there are

 

 

Detected

 

side of the pump or

no restrictions in the

 

 

 

 

color stack.

system.

F9D#

Alarm

Flow

The pump flow rate

Potential leak in the

Check the system for

 

 

Unstable

did not stabilize while

system.

leaks and run manual

 

 

Pump #

entering Idle mode.

 

stall test.

SAD1

Alarm

Atomizing

Air flow switch is

Atomizing air supply

Make sure atomizing

 

 

Solvent

active while solvent,

was not shut off before

air is shut off before

 

 

 

diluted material, or an

purging or filling spray

purging or filling the

 

 

 

unknown material is in

gun.

spray gun. Use an

 

 

 

the gun.

 

AA cutoff valve on the

 

 

 

 

 

atomizing air supply.