Operation Using a Programmable Logic Controller (PLC)

04

40108

Pump 4 Status

uint32

NONE

0

= Off

 

 

 

 

 

1

= Standby

 

 

 

 

 

2

= Busy

 

 

 

 

 

3

= Flushing

 

 

 

 

 

4

= Priming

 

 

 

 

 

 

 

05

40110

Actual Mix Flow

uint32

cc/min

1

- 1600

06

40112

Actual Mix Ratio

uint32

NONE

0

- 5000

 

 

 

 

 

 

 

07

40114

Actual Mix Potlife

uint32

sec

0

– 59940

 

 

Remaining

 

 

 

 

08

40116

Active Recipe

uint32

NONE

0

- 61

 

 

Number

 

 

 

 

09

40118

Active Recipe

uint32

NONE

1

- 30, 61

 

 

Material A

 

 

 

 

10

40120

Active Recipe

uint32

NONE

31 - 34, 61

 

 

Material B

 

 

 

 

11

40122

Active Recipe

uint32

NONE

1

- 5

 

 

Material A Flush

 

 

 

 

 

 

Sequence

 

 

 

 

12

40124

Active Recipe

uint32

NONE

1

- 5

 

 

Material B Flush

 

 

 

 

 

 

Sequence

 

 

 

 

13

40126

Active Recipe

uint32

NONE

0

- 5000

 

 

Ratio Set Point

 

 

 

 

14

40128

Active Recipe

uint32

min

0

- 999

 

 

Potlife Time Set

 

 

 

 

 

 

Point

 

 

 

 

15

40130

Actual Pump 1

uint32

cc/min

0

- 800

 

 

Flow Rate

 

 

 

 

16

40132

Actual Pump 2

uint32

cc/min

0

- 800

 

 

Flow Rate

 

 

 

 

17

40134

Actual Pump 3

uint32

cc/min

0

- 800

 

 

Flow Rate

 

 

 

 

18

40136

Actual Pump 4

uint32

cc/min

0

- 800

 

 

Flow Rate

 

 

 

 

19

40138

Actual Pump 1

uint32

PSI

0

- 1500

 

 

Fluid Pressure

 

 

 

 

20

40140

Actual Pump 2

uint32

PSI

0

- 1500

 

 

Fluid Pressure

 

 

 

 

21

40142

Actual Pump 3

uint32

PSI

0

- 1500

 

 

Fluid Pressure

 

 

 

 

22

40144

Actual Pump 4

uint32

PSI

0

- 1500

 

 

Fluid Pressure

 

 

 

 

34

332564B

Page 34