Operation Using a Programmable Logic Controller (PLC)

OUTPUT REGISTER 37: Time

The Time register contains a count of total seconds since the Unix Epoch (January 1, 1970).

The actual value reported is not important. This register should be used for diagnosing status of communication between the ProMix PD2K and the networking device.

This register is NOT currently available with the Modbus Communications Gateway Module.

OUTPUT REGISTER 38 – 40: Software Version

The Software Version registers contain the “major,” “minor,” and “build” revisions of the ADM software.

These registers are NOT currently available with the Modbus Communications Gateway Module.