Graco 332564B Initial System Setup, Flush Before Using Equipment, Valve Settings

Models: 332564B

1 104
Download 104 pages 58.79 Kb
Page 18
Image 18

Pre-Operation Tasks

Initial System Setup

1.Change optional setup selections to desired parameters, as described in Setup Mode Screens, page 66.

2.Set recipe and flush information as described in Recipe Screen, page 72 and Flush Screen, page 73.

Flush Before Using Equipment

The pump fluid section was tested with lightweight oil, which is left in the fluid passages to protect parts. To avoid contaminating your fluid with oil, flush the equipment with a compatible solvent before using the equipment.

Valve Settings

Dose valves and purge valves are factory set with the hex nut (E) 1-1/4 turns out from fully closed.

Figure 9 Valve Adjustment

18

332564B

Page 18