ELECTRONIC CONTROL INSTRUCTION
No | Function | Controlled | Description | |
Part | ||||
|
|
|
ELECTRONIC CONTROL INSTRUCTION
Controlled
No FunctionDescription
Part
1.It can be set as below according to the connection of JUMPER (J1,J2,J3)in the main PCB.
|
| 1. | 88 LED displays inside temperture |
1 | Initial | 2. | Begin to run immediately on the higher than 50℉ and |
Operation |
| begin to run after 5 minutes pause on the lower | |
|
| ||
|
|
| than 50℉. |
1.The temperature can be changed by pushing up/down buttons.
2.88 LED displays inside temperture
3.Buzzer buzzes 1time whenever a button is pressed
4.Compressor automatically turns on and off by
2 | Temperature | Compressor | 5. Comp. on/off temperature (℉) |
|
| ||||
Control | LED | Setting | 5.0 | 3.0 | 1.0 | ||||
| |||||||||
|
|
| Comp On | 5.3 | 3.5 | 0.8 | |||
|
|
| Comp OFF | ||||||
|
|
|
| ||||||
|
|
| Setting |
| |||||
|
|
| Comp On |
| |||||
|
|
| Comp OFF |
|
FREEZER /
REFRIGERATOR
4 MAIN PCB
DEFROST TIME
|
|
|
| JUMPER | P. C . B |
|
| |
| TRANSFORMER |
|
|
|
| |||
|
|
|
|
|
| |||
|
|
|
| 1,2,3 |
|
|
| |
|
|
|
|
|
|
| ||
|
|
|
|
| ||||
JUMPER | JUMPER | CONNECTION | DISCONNECTI | REMARKS | ||||
NO. | FUNCTION |
|
|
| ||||
JP1 | Unit of the | Indicated to ℃ | Indicated to ℉ |
|
| |||
Temperature | Temperature | Temperature |
|
| ||||
|
|
|
| |||||
JP2 | Mode of the |
|
|
|
| |||
control to | The controller | The controller |
|
| ||||
|
|
|
| |||||
|
| Refrigerator | of Freezer | of Refrigerator |
|
| ||
|
| / Freezer |
|
|
|
| ||
|
| Control of |
|
| Applied to the | |||
JP3 | 8 Hr | 6 Hr | Freezer model | |||||
Defrost cycle | ||||||||
|
|
|
| only. | ||||
|
|
|
|
|
|
1.Defrost Cycle : It can be set 8Hr or 6Hr by OPTION JUMPER (JP3)
ERROR CODE (FREEZER)
Code | Content | Perception Method | Refrigeration state |
|
|
|
|
|
|
|
|
|
| - short circuit | - Normal operation |
|
|
|
JUMPER
TRANSFORMER
1,2,3
P. C . B
─ |
| - Defrost | |
|
| - wire disconnection | Heater ON : 20 MINUTES |
cS | - short circuit |
| |
|
|
|
3 | Defrost | Heater | |
Function | Compressor | ||
|
2. The condition of DEFROST operation
DEFROST SENSOR.
Cond ition 1(In case the temperature checked by DEFROST SENSOR is low than 23℉); Defrost Heater (Max. 40Min. running) runs by that time
cO |
| - wire disconnection | - Time control | |
| Comp ON : 10 MINUTES | |||
cS | - short circuit | |||
Comp OFF : 6 MINUTES | ||||
|
| |||
cO | - wire disconnection |
|
18 | 19 |