SENSOR DESCRIPTION

ELECTRONIC CONTROL INSTRUCTION

SENSOR DESCRIPTION

Sensor

Model

Role

Wire Color

ELECTRONIC CONTROL INSTRUCTION

5-2-2. FUNCTION TABLE

D-sensor Freezer

Freezer

C-sensor

Refrigerator

T-sensor Refrigerator

Detect Eva coil’s temp. to terminate defrosting

Detect inside air temp. to operate comp and to indicate the inside temp. on the display PCB

Detect Eva coil’s temp. to operate comp

Detect inside air temp. to indicate the inside temp on the display PCB

WHT

BLK

BLK

WHT

No

Function

Controlled

Description

Part

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. 88 LED displays inside temperture

1

Initial

 

2. Begin to run immediately on the higher than 41and

Operation

 

begin to run after 5 minutes pause on the lower

 

 

 

 

 

than 41.

5-2. REFRIGERATOR CONTROL

5-2-1. HOW TO USE THE DISPLAY PCB PANEL

-88 LED

-It indicates setting temperature,

except defrost function

-Door Open LED

 

-Temperature can be controlled by the user.

-Factory setting is at level "35 ". Setting can be changed by pressing up/down button.

1.The temperature can be changed by pushing up/down buttons.

2.88 LED displays inside temperture

3.Buzzer buzzes 1time whenever a button is pressed

4.Compressor automatically turns on and off by C-sensor (Except errer mode)

2

Temperature

Compressor

5. Comp. on/off temperature ()

 

 

Control

LED

Setting

39

38

37

36

35

 

 

 

 

Comp On

39.0

39.0

39.0

39.0

39.0

 

 

 

Comp OFF

30.2

28.4

27.5

27.0

25.0

 

 

 

-----------------------------------------------------------------

 

 

 

Setting

34

32

30

28

 

 

 

 

Comp On

39.0

39.0

39.0

39.0

 

 

 

 

Comp OFF

23.0

21.2

19.0

17.6

 

ERROR CODE

Code

Content

Perception Method

Refrigeration state

 

 

 

 

 

 

 

 

S

T-sensor

- short circuit

- Normal operation

O

- wire disconnection

 

 

 

C-sensor

- short circuit

 

- wire disconnection

- Time control

 

 

Comp ON : 10 MINUTES

S

 

- short circuit

C-sensor

Comp OFF : 20 MINUTES

 

 

 

O

T-sensor

- wire disconnection

 

 

 

 

 

20

21

Page 11
Image 11
Turbo Air MSF-49NM, MSR-23G-1, MSR-49N, MSR-49G-2, MSR-23NM, MSF-23NM Sensor Description, Refrigerator Control, Error Code

FAQ

What is the role of the D-sensor in the freezer?

The D-sensor in the freezer is used to detect the evaporator coils temperature to terminate defrosting.

How can the temperature be controlled in the refrigerator?

The temperature in the refrigerator can be controlled using the up/down buttons on the display PCB panel.

What are the error perception methods for the T-sensor?

The error perception methods for the T-sensor include short circuit and wire disconnection.