FAULT REPAIR PROCEDURES

 

 

 

Table 5-4 Timings for Trunks

 

 

 

 

 

 

 

ITEMS FOR STATUS

 

CONDITIONS FOR SUPERVISION

TIMING SPECIFICATIONS

 

SUPERVISION

 

 

 

 

 

 

 

 

 

 

1

Detection of Call

Ring Down System

Ringing signal of more than 4 cycles

 

Termination

 

Detection by ringing signal (20Hz) from

is detected within 800 ms.

 

 

 

the opposite office.

 

 

 

Loop System

Detection within 16 ms after call

 

 

termination.

 

 

 

Detection by loop from the opposite office.

 

 

 

 

 

 

E&M System

 

 

 

 

Detection by incoming signal (ground or –

 

 

 

 

48V) on E (RG2) lead.

 

 

 

 

 

 

2

Acknowledge Signal

Wink Signal

160 ms (standard)

 

Sending

Delay Start

Timing can be assigned using ARTD

 

 

command.

 

 

 

 

 

 

 

 

 

3

Detection of Release at the

E&M System

288 ms (standard)

 

time of Incoming

Loop System

 

 

Connection

160 ms (standard)

 

 

 

 

 

 

 

Timing can be assigned using ARTD

 

 

 

 

command.

 

 

 

 

4

Timing for Restricting Call

After release of the user’s trunk or the trunk at

3070 ms (standard)

 

Origination after Release

the opposite office has been detected, a new

Timing can be assigned using ARTD

 

 

call origination is restricted.

command.

 

 

 

 

 

5

Seizure of Opposite Office

Loop System

 

 

 

 

Closure of DC loop.

 

 

 

E&M System

 

 

 

 

Supply of outgoing call signal (ground or –

 

 

 

 

48V) onto M (DL) lead.

 

 

 

 

 

 

6

Detection of Acknowledge

Wink Signal

Timing is assigned using ARTD

 

Signal

Delay Start

command.

 

 

 

 

 

 

 

7

Trunk Hold Time

Even if answer signal has not reached from the

• If DP Signal is 10 sec. (standard)

 

 

opposite office, the call is regarded as

after dial pulses are sent out

 

 

answered.

Timing can be assigned using

 

 

 

 

ARTD command.

 

 

 

 

• If PB Signal is 30 sec. (standard)

 

 

 

 

after seizure of the trunk

 

 

 

 

Timing can be assigned using

 

 

 

 

ASYD SYS 1 Index 156 (only

 

 

 

 

when 2nd Dial Tone System).

 

 

 

 

 

8

Detection of Release at the

Loop System

608 ms (standard)

 

time of Outgoing

 

Detection of polarity reversal across tip and

Timing can be assigned using ARTD

 

Connection

 

ring.

command.

 

 

E&M System

 

 

 

 

Detection of Release Signal (ground or –

 

 

 

 

48V) on E lead.

 

 

 

 

 

 

NDA-24300CHAPTER 5

Page 321

Issue 1

Page 348