FAULT REPAIR PROCEDURES

Table 5-5 Timings for Senders

 

ITEMS FOR STATUS

CONDITIONS FOR SUPERVISION

 

TIMING SPECIFICATIONS

 

SUPERVISION

 

 

 

 

 

 

 

 

 

1

Sender Acknowledge Wait

Timing limit for waiting to receive connection

4 sec. (standard)

 

Timer

acknowledgement signal from the opposite

Timing can be assigned using ASYD

 

 

office after seizing the opposite office.

SYS 1 Index 130 command.

 

 

 

 

2

Sender Prepause Timer

Time from sender seizure till sending of the

DP: 3 sec. (standard)

 

 

1st digit where connection acknowledgment is

PB: 2.5 sec. (standard)

 

 

made by interface with the opposite office.

Timing can be assigned using ASYD

 

 

 

SYS 1 Index 131 command.

 

 

 

 

 

3

Sender Inter-digit Timer

Inter-digit timing for the numbers to be sent

For DP

 

 

out by the sender.

 

10 pps: 860 ms (standard)

 

 

 

 

20 pps: 460 ms (standard)

 

 

 

 

Timing can be assigned using

 

 

 

 

ASYD SYS 1 Index. 132 com-

 

 

 

 

mand.

 

 

 

For PB

 

 

 

 

60 ms/120 ms (to be selected by

 

 

 

 

ONSG of ARTD command.)

 

 

 

 

Timing can be changed using

 

 

 

 

ASYD SYS 1 Index 133 com-

 

 

 

 

mand.

 

 

 

 

 