Ethernet bandwidth

Chapter 2 Fault Descriptions

Access Point /Bridge Faults

Table 2-1

Access Point Faults (continued)

 

 

 

 

 

 

Fault Description

Explanation

Related Setting

Recommended Action

 

 

 

 

Ethernet bandwidth

The fault threshold set for the

Manage Fault

Verify that the fault threshold is set

utilization is Degraded

degraded state has been exceeded.

Settings > Access

correctly.

(utilization %)

 

When this fault is cleared, the

Point/Point

If the threshold is set correctly, review

 

 

Thresholds >

 

 

following message displays: Ethernet

your network to determine the action

 

 

bandwidth utilization is OK.

Ethernet Port

necessary to clear the fault condition.

 

 

Utilization

 

 

 

 

 

 

 

 

Ethernet bandwidth

The fault threshold set for the

Manage Fault

Verify that the fault threshold is set

utilization is

 

overloaded state has been exceeded.

Settings > Access

correctly.

Overloaded

 

When this fault is cleared, the

Point/Bridge

If the threshold is set correctly, review

(utilization %)

 

Thresholds >

 

following message displays: Ethernet

your network to determine the action

 

 

bandwidth utilization is OK.

Ethernet Port

necessary to clear the fault condition.

 

 

Utilization

 

 

 

 

 

 

 

 

Excessive frame counts:

See IDS (Intrusion Detection System) Faults, page 2-14

 

Action

Association

Authentication

Deauthentication

Disassociation

Probe

Reassociation

Firmware version

The wrong version number for policy

Manage Fault

Make sure that the firmware version

policy violation

checking has been entered.

Settings > Access

that is entered in the policy setting

(version number)

When this fault is cleared, the

Point/Bridge

matches the firmware version on the

 

Policies >

access point.

 

following message displays:

 

Firmware Version

 

 

Firmware version is valid.

 

 

 

 

 

 

 

 

 

The access point is running an

 

Make sure that you have entered

 

unauthorized firmware version.

 

authorized versions in the policy

 

When this fault is cleared, the

 

setting.

 

 

 

 

following message displays:

 

Update the firmware on the access

 

Firmware version is valid.

 

point to an authorized version.

 

 

 

 