MODEL

PGB58B0902A

PGB58B1152A

PGB58B1352A

 

 

 

 

Cooling Capacity Btuh

59,500

59,500

59,500

SEER

11.10

11.10

11.10

 

 

 

 

Heating

 

 

 

 

 

 

 

Input Btuh

90,000

115,000

135,000

 

 

 

 

Output Btuh

72,000

92,000

108,000

 

 

 

 

AFUE

81.4

79.9

80.5

 

 

 

 

Temperature Rise °F

25-55

25-55

25-55

 

 

 

 

Number of Burners

4

4

4

 

 

 

 

Compressor

 

 

 

 

 

 

 

R.L. Amps

28.8

28.8

28.8

 

 

 

 

L.R. Amps

169

169

169

 

 

 

 

Condenser Coil

 

 

 

Face Area (sq. ft.)

17.2

17.2

17.2

 

 

 

 

Rows Deep

2

2

2

 

 

 

 

Fins/Inch

17

17

17

 

 

 

 

Condenser Fan

 

 

 

 

 

 

 

Diameter (in.)

24

24

24

 

 

 

 

CFM

4700

4700

4700

 

 

 

 

Condenser Fan Motor

 

 

 

 

 

 

 

Horsepower

1/3

1/3

1/3

 

 

 

 

R.L. Amps

2.5

2.5

2.5

 

 

 

 

L.R. Amps

6.4

6.4

6.4

 

 

 

 

Blower Motor

 

 

 

 

 

 

 

Horsepower

3/4

3/4

3/4

 

 

 

 

R.L. Amps

5.6

5.6

5.6

 

 

 

 

L.R. Amps

12.9

12.9

12.9

 

 

 

 

Blower Wheel Dia. x Width (in.)

11X8

11X8

11X8

 

 

 

 

Rated CFM, Cooling

1750

1750

1750

 

 

 

 

Max. External

0.5" wc

0.5" wc

0.5" wc

 

 

 

 

Combustion Blower

 

 

 

 

 

 

 

Diameter x Width (in.)

4 x 1.25

4 x 1.25

4 x 1.25

 

 

 

 

No.

1

1

1

 

 

 

 

Condenser Blower Motor

 

 

 

 

 

 

 

H.P.

1/32

1/32

1/32

 

 

 

 

F.L. Amps.

0.5

0.5

0.5

 

 

 

 

Press. Switch Setting (" W.C.)

-0.65

-0.65

-0.65

 

 

 

 

Ignition - Lockout Timing (sec.)

4

4

4

 

 

 

 

Flame Sense Current (microamps)

 

 

 

 

 

 

 

Minimum

1

1

1

 

 

 

 

Maximum

6

6

6

 

 

 

 

Evaporator Coil

 

 

 

Face Area (Sq. Ft.)

5.7

5.7

5.7

 

 

 

 

Rows Deep

4

4

4

 

 

 

 

Fins/Inch

15

15

15

 

 

 

 

External Filter Size (Sq. Ft.)

 

 

 

Drain Line Size (in.)

3/4

3/4

3/4

 

 

 

 

Expansion Device (Cooling)

TEV

TEV

TEV

 

 

 

 

Refrigerant Charge

Refer to unit name plate for correct charge

 

 

 

 

Power Supply**

208/230-60-1

208/230-60-1

208/230-60-1

 

 

 

 

Min. Circuit Ampacity

33.75

33.75

33.75

 

 

 

 

Max. Overcurrent Device

50

50

50

 

 

 

 

Electrical Entrance Size

 

 

 

 

 

 

 

Power Supply

1 1/4", 1 1/2", 2"

1 1/4", 1 1/2", 2"

1 1/4", 1 1/2", 2"

 

 

 

 

Low Voltage

7/8"

7/8"

7/8"

 

 

 

 

Approx. Shipping Weight (lbs)

531

531

531

 

 

 

 

Table 1C

Gas Pack Specifications

4

Image 4
Contents Table of Contents PGB58BUnit Specifications Gas Pack SpecificationsHeating TEV PGC Temperature Rise Table PGB CFM& Temperature Rise vs. External Static Pressure TableII. Safety Information To The InstallerTo The Owner If you smell gasAll Installations Ground Level Installations OnlyRooftop Installations Only III. General InformationRequired Clearances For All Installations Transportation Damage IV. Rigging and HandlingLocating The Thermostat Gas Piping Connecting The Gas Piping Natural GasGas Piping Checking The Gas Piping Proper Piping PracticeTanks And Piping for Propane Gas Units Vl. Electrical Wiring Heat Anticipator Setting Vll. Circulating Air and FiltersUnit Voltage Airflow ConversionTypical Wiring Rooftop Typical Electrical WiringFilter Installation Filter Access DoorFilters VIII. Flue Vent IX. Condensate DrainAir Inlet Hood and Flue Hood Typical Condensate DrainPGB Timing Chart for Normal Cooling Operation Timing Chart for Normal Robertshaw Operation PGB & PGCPGC Timing Chart for Normal Cooling Operation Heating Sequence of Operations PGB & PGC XIl. Startup and AdjustmentXI. Cooling Sequence of Operations Reset After Lock-out Rollout Protection Shown Without Heat ShieldPosition of Limit Control Gas Valve Operating Instructions HeatingMeasuring Inlet Gas Pressure Alternate Method Checking External Static Pressure Changing Blower Speeds PGC UnitsChanging Blower Speeds PGB Units Check Limit And Fan ControlFan and Limit Control Short Cycle Protector LocationHigh Pressure Protection Devices Scroll CompressorsReciprocating Compressor Operating Instructions coolingXIII. Maintenance Blower Motor and HousingInduced Draft Motor Removal of Fan MotorXIV. Accessories and Functional Parts Accessory ListFunctional Parts List Transition Kit Pressure DropXV. Typical Cooling Performance Data PGCPsig XVI. Wiring Diagram PGC24PGC PGC Volt Installation PGB G R

PGB58B, PGC(24-60)B specifications

Amana, a trusted name in heating and cooling, offers several high-efficiency gas furnace models, including the PGC(24-60)B and PGB58B. These furnaces combine innovation, reliability, and advanced technology to provide an optimal heating solution for any home.

One of the standout features of the Amana PGC(24-60)B is its modulating heating capability. This technology allows the furnace to operate at different heating levels based on the home’s demands. Instead of simply turning on and off, the PGC adjusts its output to maintain a consistent temperature, promoting energy efficiency and comfort. This not only reduces energy consumption but also minimizes temperature fluctuations, providing a more comfortable indoor environment.

The PGB58B model is designed with a focus on efficiency, boasting an Annual Fuel Utilization Efficiency (AFUE) rating of up to 96%. This means that a higher percentage of the fuel used is converted into heat, making it one of the most efficient choices available. The combination of high-efficiency design and advanced components makes the PGB58B an excellent option for homeowners looking to reduce their energy bills while enjoying reliable heating performance.

Both models come equipped with a durable casing, ensuring longevity and performance. The rust-resistant and heavy-gauge steel construction protects against harsh weather conditions, making them suitable for various climates. Additionally, they feature a multi-speed blower motor, which optimizes airflow and enhances comfort by evenly distributing warm air throughout the home.

Advanced diagnostics and self-monitoring capabilities are integral to these models. The built-in diagnostic system enables quick identification of performance issues, allowing for timely maintenance and reducing repair costs. Furthermore, these furnaces are designed to be compatible with smart home technology, allowing homeowners to control their heating systems remotely and maximize energy efficiency.

In summary, the Amana PGC(24-60)B and PGB58B gas furnaces stand out for their innovative features and commitment to energy efficiency. With modulating heating, high AFUE ratings, durable construction, and smart technology compatibility, they offer reliable heating solutions that ensure comfort while keeping energy costs low. Homeowners can feel confident in their investment, knowing they have chosen a furnace that prioritizes both performance and sustainability.