Repair
Replacing thermoblock and NTC
Tools:
-Torx screwdrivers T10, T30
-
-Torque wrench
Procedure:
1.Follow general disassembly (see page 16).
2.Remove screw (23) and detach holder
(48)with flow meter (47).
3.Remove 3 screws (23) and separate thermoblock (40) with support (40) from chassis.
4.Remove screw M3.5 x 25, washer and rubber gasket and separate thermoblock
(40)from its support.
5.Remove screw (38) and separate fine wire fuse (900) from thermoblock.
6.Remove electronic housing (28).
7.Unplug NTC connector from electronic control board (28).
8.Remove NTC (43) from thermoblock and replace it if defective.
9.Remove clips (13) and hose connectors (16, 26) from thermoblock.
10.Remove ground wire and electrical connections from thermoblock.
11.Replace defective thermoblock.
12.Assemble in reverse sequence.
Service Manual EF 473 / EF 474
)Use a torque wrench (90 - 110 Ncm) to tighten NTC temperature sensor (43) with spring washer (42).
|
| 47 + 48 |
|
| 23 |
28 | M3.5 x 25 | |
38 |
| |
16 | 40 | |
|
| |
13 |
|
|
26 | 38 | 40 |
| 39 | |
|
| |
| 43 | 23 |
| 42 | |
| 900 | |
18 |
| Version 1.0 en |