Nespresso EF 474, EF 473 manual Measuring flow rate, Procedure

Page 28

Repair

Measuring flow rate

Procedure:

1.Fill water tank.

2.Insert pressure plug in capsule inlet.

3.Press down closing handle lightly till pressure plug fits in capsule cage.

4.Pull off holding device. The pressure plug clamps itself to the capsule cage.

5.Position measuring beaker underneath exit tube of pressure plug.

6.Switch on machine.

7.Press button "large cup" after heating-up.

8.Open valve fully till water begins to flow.

9.Close valve until 12 bar are indicated.

)The manometer must be observed continuously and the pressure regulated using the valve if necessary. With increasing temperature the pressure also increases, if necessary readjust the pressure to 12 bar.

10.Perform measurement for approx. 30 sec.

11.There must be at least 60-120 ml water in the measuring beaker.

2

1

 

Notice:

 

-With a flow of < 60 ml the pump is defective or there is a leak in the system.

-Large fluctuations in the pressure gauge readings (± 4 bar) during measurement are indicative of a defective pump.

3

4

8 9

7

6

5

Service Manual EF 473 / EF 474

28

Version 1.0 en

Image 28
Contents Essenza FS Contents Preface Main Components OverviewOverview of rating plates Serial number codificationWater circuit Technical data Preparation OperationDo not insert a capsule yet Procedure to fill water system Fill water systemMaking coffee Programming Reset to factory settings Empty water system Coffee machine status Operating modes Left Coffee buttons LED signals RightOperating status of coffee buttons Troubleshooting Checking the machine on receiptFurther details in order to take decision Repair General disassemblyTool Replacing thermoblock and NTC ToolsProcedure for flow meter Replacing flow meter and On/Off switchProcedure for On/Off switch Replacing pump Replacing electronic control board with button prints Replacing compact brewing unit CBU Pump Pump On/Off switch Repair Descaling Carefully read safety instructions on decalcifier packageDescaling Rinsing SecMeasuring flow rate Checking for leaks and pump pressure Preparation unplug machine from mainsSwitch off machine Open valve to empty pressure gauge Measuring coffee temperature Coffee temperature should be approx C ± 3 C 187 F ± 5.4 FDaily care and final cleaning Procedure machine is switched offRepair accessories Spare PartsSpare parts EF Electronic set 230V EF Coffee outlet & front ring EF 471 package 29 39154 Coffee buttonEF 30 43061 Espresso button EF 26392 Version 1.0 en