14. OPERATING PROCEDURES

14.6 TARE/SAVE FUNCTION PROCEDURES

14.6TARE/SAVE FUNCTION PROCEDURES

Menu: REG., M.DOWN, or REWRAP

Mode: WEIGH or FIX (Tare % function is available in WEIGH mode only.)

There aretwo kinds of tare subtraction procedures, one is “Direct tare”, the other is “Preset tare “. The SAVE key is used to save the tare, unit price, and PLU data after taking a commodity from the platter.

Place a container on the platter.

(Ex. 0.200 lb)

Press:

Enter the PLU #.

0.200 lb

T

1

0

0

 

 

 

2

0

0

 

 

 

T

Press:

Place a container on the platter

Tare %

1

0

0

 

 

 

%

Press:

PLU

Tare %

%

The PLU data and tare are

SAVE

saved.

Place a commodity on the

 

platter.

 

(Ex. 1.000 lb)

 

MANUAL:

:AUTO

 

*

 

 

The label is issued.

1

0

0

 

 

 

%

Remove the Commodity together with the container.

 

Press:

 

C

 

 

 

CA type

 

 

 

US type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PLU

Press:

 

0

 

 

 

 

 

 

 

 

 

T

Press:

Press:

Press:

C

 

 

 

 

 

 

Remove the commodity together with the container.

PLU

Press:

NOTES: 1. Tare subtraction is available up to 2.000 lb. for the US type, and up to 1.000kg (2.205lb) for the CA/QR type. When tare subtraction is in operation, however, the scalable range for net weight becomes less by the amount of the tare. (Net weight-Gross weight-Tare)

2.Preset tare must be a multiple of 2 g for CA/QR type (Kg scale) and a multiple of 0.005 lb for US/CA type (Lb scale).

3.The tare % function is available when the Initial Setting #8-7 is set to 1 (SL-9000) or #28-4 is set to 1 (SL-9000N). The speed key #70 will function as the % key (Refer to page 5-3). Set a tare % within the range from 0.0 to 99.9.

4.When a commodity is placed on the platter and the calculated tare exceeds the maximum, a “TARE WEIGH OVER” error will occur.