PROGRAMMING THE BREWER (cont.)

CALIBRATE FLOW (cont.)

CALIBRATE FLOW?

NO

YES

EXIT TO THE

 

NEXT FUNCTION

 

SCREEN

 

SPRAYHEAD CAL?

NO

YES

CONTAINER RDY?

QUIT

YES

CALIBRATE SPRAY

PRESSBREWSTART

BREW PRESSED

COUNTS DOWN

CALIBRATE SPRAY

TO ZERO

 

60 SEC TO FINISH

 

 

 

AFTER 1 MINUTE

ENTER OZ XX.X

(-) DONE (+)

NEW SPRAY FLOW

XX.X OZ/M

P2307

Procedures to calibrate the bypass flow rate:

1.Place a container, accurately graduated in ounces, and with a minimum capacity of 60 ounces, below the funnel on the brewer.

2.Press and hold the upper right hidden switch until the display reads UNITS.Release the switch, then press and release switch until the display reads

CALIBRATE FLOW.

3.Press and release YES to advance to the SPRAY- HEAD CAL? function screen. (Pressing NO in the CALIBRATE FLOW screen will advance to the next function screen, BREW COUNTERS).

4.Press and release NO to advance to the BYPASS CALIBRATION screen.

5.Press and release the YES pad. The display should read CONTAINER READY? If the container is under the funnel, press YES. The display should read CALIBRATE BYPASS .. PRESS BREW TO

START.

6.Press and release the BREW switch. The display should read CALIBRATE BYPASS .. 60 SEC TO FINISH. The 60 second timer on the display will count down to zero. When the counter reaches zero, the display will change to ENTER OZ., along with a number measured in ounces per minute.

CALIBRATE FLOW?

NO

YES

EXIT TO THE

 

NEXT FUNCTION

 

SCREEN

 

SPRAYHEAD CAL?

NO

YES

BYPASS CAL?

NO

YES

CONTAINER RDY?

NOYES

 

 

CALIBRATE BYPASS

 

 

PRESS BREW START

 

 

 

 

 

 

 

 

 

 

BREW PRESSED

COUNTS DOWN

 

 

CALIBRATE BYPASS

TO ZERO

 

60 SEC TO FINISH

 

 

AFTER 1 MINUTE

ENTER OZ XX.X (-) DONE (+)

NEW BYPAS FLOW

P2314

XX.X OZ/M

 