TROUBLESHOOTING (cont.)

Screen Displayed

FILL TIME TOO

LONG

CHECK WATER

SUPPLY

TEMP SENSOR

OUT OF RANGE

CHECK FOR BAD

CONNECTIONS

TEMP SENSOR

OUT OF RANGE

CHECK WIRE FOR

SHORTS

Possible Cause

Troubleshooting Procedures

1.

Water shut off to brewer

Check water supply shut-off

2.

Inlet Solenoid Valve failure

Service required

3.

Control Board Failure

Service required

1. Temperature Sensor Probe wire(s)

Check wire and connection of both

broken or not making connection.

black and white wires of temperature

 

probe.

1. Temperature Sensor Probe

Check to confirm that wire(s) are

wire(s) shorted to housing, or to

not pinched between two surfaces

each other.

or connected to each other.