TROUBLESHOOTING (cont.)
Screen Displayed
FILL TIME TOO
LONG
CHECK WATER
SUPPLY
TEMP SENSOR
OUT OF RANGE
CHECK FOR BAD
CONNECTIONS
TEMP SENSOR
OUT OF RANGE
CHECK WIRE FOR
SHORTS
Possible Cause | Troubleshooting Procedures | |
1. | Water shut off to brewer | Check water supply |
2. | Inlet Solenoid Valve failure | Service required |
3. | Control Board Failure | Service required |
1. Temperature Sensor Probe wire(s) | Check wire and connection of both |
broken or not making connection. | black and white wires of temperature |
| probe. |
1. Temperature Sensor Probe | Check to confirm that wire(s) are |
wire(s) shorted to housing, or to | not pinched between two surfaces |
each other. | or connected to each other. |
Page 43 | 35879.1 071405 |
|