USER NOTICES (cont.)
To reduce the risk of electric shock, do not remove or open cover.
No
Authorized service personnel only. Disconnect power before servicing.
37881.0002
ELECTRICAL REQUIREMENTS (Models with power cord)
WARNING - The brewer must be disconnected from the power source until specified in Initial
Refer to Data Plate on the Brewer, and local/national electrical codes to determine circuit requirements.
WHITE | WHITE | N | |
NEUTRAL | NEUTRAL | ||
| |||
L1 BLACK | L1 BLACK | L1 | |
|
| ||
GREEN | GREEN G |
120 volt ac single phase,
60 Hz models
Note: This electrical service consists of 2 current carrying conductors (Neutral and L1) and a separate conductor for earth ground.
L2 RED | L2 RED | L2 | |
|
| ||
WHITE | WHITE | N | |
NEUTRAL | NEUTRAL | ||
| |||
L1 BLACK | L1 BLACK | L1 | |
|
| ||
GREEN | GREEN | G |
120/208 and 120/240 volt ac single phase, 60 Hz models
Note: This electrical service consists of 3 current carrying conductors (Neutral, L1 and L2) and a separate conductor for earth ground.
ELECTRICAL HOOK-UP
1.An electrician must provide electrical service.
2.Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.
NOTE - The brewer is shipped without a plug on the power cord. Qualified service personnel must select and install the proper UL listed grounding type attachment plug specified on the rear of the brewer.
3.Install the specified plug on the attached power cord.
4.Remove the front panel beneath the sprayheads to gain access to the terminal block.
5.Connect the brewer to the power source and verify the voltage at the terminal block before proceeding.
6.If plumbing is to be hooked up later be sure the brewer is disconnected from the power source. If plumb- ing has been hooked up, the brewer is ready for Initial
WARNING – Electrical connections must be made as specified above. Failure to follow these instructions can result in personal injury, property or equipment damage.
Page 5 | 35879.1 110507 |
|