PROGRAMMING THE BREWER (cont.)

SERVICE TOOLS

This function allows the testing of individual com- ponents and the ability to check switches for proper function. This function also tests the Soft Heat server's status on the brewer (in place or removed), and the funnel sensor coil's frequency (diagnostic tool for troubleshooting purposes only).

SERVICE TOOLS?

NO YES

EXIT TO

NEXT FUNCTION

SCREEN

TEST OUTPUTS?

NO YES

TEST SWITCHES? PRESS AND RELEASE

NO

YES

 

® SYMBOL

 

 

 

BREW VALVE

ON NEXT OFF

NOTHING PRESSED

NEXT COMPONENT

TO BE TESTED

TEST FREQUENCY?

NO

YES

 

125.0 KHZ. 4

 

4 125.0 KHZ.

EXIT TO

 

NEXT FUNCTION

PRESS AND RELEASE

SCREEN

® SYMBOL

 

P2757

Testing individual components (outputs):

This will allow the operator to test the operation of individual components and outputs of the brewer. The components that can be individually tested are as follows:

Brew Valve

Bypass Valve

Funnel Lock (Optional)

Refill Valve

Tank Heaters

Heater Contactor

Procedure to test components (outputs):

1.Place brew funnels into rails on the brewer.

2.Place a Soft Heat server beneath the brew fun- nel.

3.Press and hold the upper right hidden switch until the display reads UNITS. Release the switch, then press and release switch until the display reads

SERVICE TOOLS.

4.Press YES to run tests on various components and outputs within the brewer. Pressing NO will exit this function and advance to the next function screen.

5.The display should read TEST OUTPUTS.

6.Press and release YES. The display should read

BREW VALVE.

7.To test BREW VALVE, press ON. If the brew valve is functional, water should run from the brewer.

8.Press OFF to end flow of water.

9.Press NEXT to advance to the next component to be tested.

NOTE: To bypass testing any component, press NEXT to advance to the next one, without testing the previ- ous component.

10.To test BREW BYPASS, press ON. If the bypass valve is functional, water should run from the brew bypass.

11.Press OFF to end flow of water.

12.Press NEXT to advance to the next component to be tested.

13.To test FUNNEL LOCK, press ON. If the funnel lock is functional, the lock will come down to hold the funnel in place.

Page 37

35879.1 071405

 

Page 37
Image 37