14. OPERATING PROCEDURES

14.5ISSUING LABELS WITH NET WEIGHT STATEMENT (FOR US TYPE ONLY)

14.5ISSUING LABELS WITH NET WEIGHT STATEMENT (FOR US TYPE ONLY)

Menu: REG., M.DOWN, or REWRAP

Mode: FIX

When the initial settings #1-7 and #1-8 are set to 1, a Net Weight Statement is printed on the label. A unit price and a tare registered in each PLU are printed as a price and a net weight.

Example) The preset Price is $2.10 and the preset Net Weight is 12 oz. The store knows that the actual Net Weight of this commodity is 19 oz. and decides to sell it at $2.00.

Enter the PLU #.

8

1

6

Press

PLU

 

 

 

Initial set

#7-1: 0

 

 

Enter the new price.

2

0

0

Press:

 

 

 

 

 

 

*

Enter the new weight.

 

 

 

 

 

 

 

 

 

 

(unit of weight: oz)

 

 

 

 

 

 

displayed in the incremental

 

 

 

 

 

 

display method, i.e., the data

 

1

9

 

 

is shifted to the left as each

 

 

 

 

 

 

digit value is entered.)

 

 

 

 

 

 

Initial set #1-7:1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Initial set #7-1:1

Initial set #1-7:0

Press:

Enter the quantity.

Press:

AUTO

FOR

3

*

MANUAL

The label is issued. (Labels of identical print data will automatically be issued consecutively by peeling the label off the backing paper.)

The label is issued.

C

Press, to cancel label issue temporarily.

C

Press, to cancel label issue.

PLU

Press, to return the PLU data to the PLU file.

14- 9

Page 74
Image 74
Toshiba SL-9000-FFR-QR, SL-9000N-FFR-QR, SL-9000N-FFR-CA Issuing Labels with NET Weight Statement for US Type only, Plu