Installing Line for Gas Logs

MHSC fireplaces are designed to accept a 1/2" (13 mm) gas line for installation of an approved gas appliance. (MHSC manufactures a wide variety of gas logs for use in MHSC fireplaces.)

Be sure to have the appliance installed in accordance with building codes.

Gas connection may enter from either left or right side of the fireplace.

Locate appropriate gas line in the outer casing of fire- place and remove insulation from gas line tube. (Fig. 26)

From inside the fireplace, locate the knockout on the firebrick -- be sure you are on the appropriate or "gas line" side of the fireplace. Using a flat bladed screw- driver or small chisel and hammer, carefully tap around the knockout until it loosens and falls out.

Install 1/2" (13 mm) certified gas pipe through opening. After gas pipe installation is complete, use insulation that was removed from gas line tube to repack space around the pipe. Material should be inserted from outside of the fireplace and packed tightly to totally seal between the pipe and tube.

NOTE: Gas pipe should not come in contact with any wood structures until it has reached a point at least one (1) inch away from fireplace side.

NOTE: When installing an ANSI Z21.11.2 ventless ap- pliance the finishing material used for the mantel must be rated at 250°F or greater.

BTU input of a gas appliance installed in fireplace should be rated less than 100,000 BTU/Hr.

Gas pipe installation is intended for connection to a decorative gas appliance only when (1.) incorporating an automatic shutoff device and (2.) complying with the Standard for Decorative Gas Appliances for Installa- tion in Vented Fireplaces (ANSI Z21.60) or CSA draft requirements for Gas-Fired Log Lighters for Woodburn- ing Fireplaces (Draft No. 4, August 1993).

Decorative gas appliance should be installed in accor- dance with the National Fuel Gas Code, ANSI Z223.1/

NFPA 54 (latest edition).

 

Hole in Outer Casing

Fireplace Top View

 

 

 

 

 

1"

 

 

Gas Line

Min.

Supply

 

Tube

 

Line

 

Ceramic

 

Repack Insula-

 

Knockout

 

tion

 

 

 

1/2"

 

Hole in

 

 

 

Casing

 

 

 

 

 

Ceramic

 

 

 

Knockout

 

 

 

(Both sides)

 

 

 

FP560

Fig. 26

Gas line access.

 

 

CAUTION: WHEN USING DECORATIVE GAS APPLIANCE, FLUE DAMPER MUST BE SET IN FULLY OPEN POSITION. IF YOU HAVE GLASS DOORS ON THE FIREPLACE, THEY MUST ALSO BE FULLY OPENED.

WARNING: DO NOT OPERATE AN UNVENTED GAS LOG SET IN THIS FIRE- PLACE WITH THE CHIMNEY REMOVED.

WARNING: WHEN INSTALLING AN UNVENTED GAS LOG SET, THE MHSC MODEL CABL OR CABR 4" ADJUSTABLE HOOD MUST BE USED.

If installing an unvented gas log set, refer to statement below:

Only unvented gas logsets which have been found to com- ply with the Standard for Unvented Room Heaters, ANSI Z21.11.2, are to be installed in this fireplace.

18

20014528

Image 18
Contents WR/WC Series Safety Information Table of ContentsWR400 Series Woodburning Fireplace WR500 Series Woodburning Fireplace Chase Installation Front Width Back Width DepthRise 30˚ Elbow OffsetsIllustration Key OffsetPlanning the Chimney Run Planning InformationMounting the Fireplace Ten Foot RuleChimney Supports InstallationChase Installation Insulating Fireplace Enclosure For Cold ClimatesChimney Setup Installing Electrical Wire For Circulator ModelsInstall Fan Kit Assembly FramingCeiling Chimney Hole Possible Obstructions Straight-Up Chimney InstallationOffset Installation Cutting the HoleInstalling the Chimney System Positioning, Safety Strips Securing the FireplaceInstalling Outside Air Kit Angle of Chimney at CeilingAttic Installation Ceiling Installation Installing the Firestop Spacer Ceiling HoleProper Firestop Spacer Installation Canadian Requirements For Insulation ShieldAdditional Ceilings Continue Installing Pipe to Complete RunInstall Remainder of Chimney Sections Penetrating the RoofInstalling Top Housing or Termination Installing Chimney In a ChaseFinishing Finish Wall Top View MaterialFor On-Site Construction Side Wall Protection Hearth InstallationMinimum Wall Clearances Noncombustible Surround FacingSide View EH2416 458Installing Line for Gas Logs Fireplace Top ViewWR400/500, WC400/500 Series Description WR/WC400 WR/WC500Accessories Accessory Description Model NumberChimney Components CCE-SK AIS-SKWhat is Not Covered Limitations and ExclusionsMhsc