Page 8

WR / WC Series Woodburning Fireplace

Chimney Supports

The chimney system is supported by the fireplace for vertical chimney heights less than 30' (9m) above the hearth. Chimney supports are required if the vertical height exceeds 30' (9m) with SK8 chimneys or 20' (6m) with 3-wall chimneys. Locate chimney supports at ceil- ing holes or other structural framing at 30' (9m) (SK8) or 20' (6m) (3-wall) heights. Spacing between chimney supports must not exceed 30' (9m) (SK8) or 20' (6m) (3-wall). Use Chimney Support Model SKCS8. (Note:

The SKCS8 can not be mounted directly to the fireplace.) Support provided by elbow straps fulfills the support requirement only if they are spaced as previ- ously described. (A chimney support is 2¹⁄₂" (64mm) long when installed.)

Angled chimney runs require a support every 6' (1.8m) in addition to the elbow straps. Chimney supports are used for this function. (Fig. 9)

Chase Installation

A chase is a vertical box like structure which encloses the fireplace and/or chimney. Chases are typically built on the outside of the house with fireplace opening cut into the outer wall of a room. (Page 5, Fig. 5)

If you need help in determining fireplace location or how the chimney system should be run, contact your MHSC dealer for assistance.

Chimney Sup- port Strap

SKCS8

FP284

Fig. 9 Chimney support installation

Installation

Insulating Fireplace Enclosure

for Cold Climates

If you live in a cold climate, it is not required but highly recommended that you insulate fireplace enclosure to eliminate cold air penetration as much as possible.

Insulate base of fireplace with a noncombustible in- sulation rated for a minimum of 300°F. Insulating is very important for outside wall installations over a concrete slab. If fireplace is installed on a platform, insulation should be placed on top of the platform before fireplace is set. (Fig. 10)

When a fireplace is installed in a chase or on an outside wall, enclosure should be treated like any outside wall in a home. Insulation should be in- stalled on the inside wall as well as the outside wall(s). In a chase, it is also a good idea to install a firestop at the first ceiling level above the fireplace and enclose the chase with sheeting material. Insu- lation may then be installed above sheeting material to assure the space around the fireplace is totally protected. (Fig. 5)

When installing the chimney, DO NOT caulk be- tween outer pipe and firestop. It is vital that some air be allowed to flow through this very thin gap.

CAUTION: WHEN INSTALLING A FIREPLACE IN AN INSULATED ENCLOSURE, BE SURE ALL RE- QUIRED AIR SPACES ARE MAINTAINED. (Page

14, Fig. 20)

20014528

Image 8
Contents WR/WC Series Safety Information Table of ContentsWR400 Series Woodburning Fireplace WR500 Series Woodburning Fireplace Chase Installation Front Width Back Width Depth30˚ Elbow Offsets Illustration KeyRise OffsetPlanning Information Mounting the FireplacePlanning the Chimney Run Ten Foot RuleInstallation Chase InstallationChimney Supports Insulating Fireplace Enclosure For Cold ClimatesInstalling Electrical Wire For Circulator Models Install Fan Kit AssemblyChimney Setup FramingStraight-Up Chimney Installation Offset InstallationCeiling Chimney Hole Possible Obstructions Cutting the HolePositioning, Safety Strips Securing the Fireplace Installing Outside Air KitInstalling the Chimney System Angle of Chimney at CeilingInstalling the Firestop Spacer Ceiling Hole Proper Firestop Spacer InstallationAttic Installation Ceiling Installation Canadian Requirements For Insulation ShieldContinue Installing Pipe to Complete Run Install Remainder of Chimney SectionsAdditional Ceilings Penetrating the RoofFinishing Finish Wall Installing Top Housing or TerminationInstalling Chimney In a Chase Top View MaterialSide Wall Protection Hearth Installation Minimum Wall ClearancesFor On-Site Construction Noncombustible Surround FacingSide View EH2416 458Installing Line for Gas Logs Fireplace Top ViewWR400/500, WC400/500 Series Description WR/WC400 WR/WC500Accessories Accessory Description Model NumberChimney Components CCE-SK AIS-SKWhat is Not Covered Limitations and ExclusionsMhsc