Crown IQSMX-6, IQAMB-5 manual Selecting the IQ Address and Communication Parameters

Page 12

AMB-5 /SMX-6IQ Mixer/Multiplexer

Crown Bus loops, 1 and 2, and an IQ–SMX-6 is to be installed into loop 1 and given an address of 114. No other IQ–SMX-6 can be given the same address in loop 1. However, an IQ–SMX-6 in loop 2 can have the same address.

Different IQ components in the same Crown Bus loop can have the same address. For example, both an IQ– SMX-6 and an IQ–AMB-5 can use address 114 in the same loop.

A valid IQ address is any number from 1 to 250. Do not use a number higher than 250 since they are reserved for special use. An address of “0” (zero) should never be used.

3.2.2Connect the mixer/multiplexer to the IQ System via the Crown Bus

The IQ components in a Crown Bus loop are wired sequentially. The loop begins and ends with the IQ interface. The output of one IQ component “loops” to the input of the next and so on as shown in Figure 3.10.

There are three different types of connectors used for Crown Bus wiring on IQ components. These include DIN connectors, RJ-45 connectors, and removable barrier strip plugs. IQ mixer/multiplexers use four ter- minal removable barrier strip connectors that accept plugs like the one shown in Figure 3.4.

Figure 3.3 Selecting the IQ Address and Communication Parameters

Page 12

IQ–AMB-5 / IQ–SMX-6 Reference Manual

Image 12
Contents AMB-5/*SMX-6 Three Year Full Warranty Important Safety Instructions Lightning Bolt Symbol Exclamation Mark SymbolCrown Audio Technical Support Group Quick Install Procedure Contents Illustrations IQ Audio In DepthWelcome UnpackingControls, Connectors & Indicators IQ Mixer / Multiplexer Controls, Connectors & IndicatorsHardware Installation Connecting to a Host Computer StepConnecting to the Crown Bus Step Set the IQ Address SwitchSelecting the IQ Address and Communication Parameters PIN Connect the Audio Wiring Step Connect Auxiliary Devices StepOperation HardwareAutomatic Mixing Features Computerized Control and MonitoringDuck Priority Input CompressorGate Count Ambience IQ-AMB-5 onlyTechnical Information Crown Local Net IQ-SMX-6 onlyAudio Input SectionControl and Interface Section IQ-AMB-5 Block Diagram IQ-SMX-6 Block Diagram Closer Look at Audio Signal Wiring IQ Audio In DepthInput Cable ShieldedTwin-lead IQ-AMB-5 Ambient Sensing InputStack Inputs Audio Output SectionCorrect way to wire stacked units is shown below Paralleling inputsUsing the AUX Port 15 Internal Auxiliary CircuitWiring the Crown Local Net Mixer/Multiplexer as a 1-Loop IQ InterfaceCloser Look at Crown Bus Wiring IQ Address Switch IQ Address TablesIQ Address Switch Settings from 126 to Factory Service Crown Audio Customer ServiceFactory Service Shipping Instructions Crown Factory Service Information

IQAMB-5, IQSMX-6 specifications

Crown IQSMX-6 and IQAMB-5 are revolutionary products designed for various applications in the electronic and automotive sectors, delivering high performance, reliability, and advanced features. These models showcase Crown's commitment to delivering cutting-edge solutions tailored for modern needs.

The Crown IQSMX-6 is a compact, high-efficiency power module equipped with a variety of features aimed at optimizing performance while minimizing energy consumption. One of its standout characteristics is the integration of advanced thermal management technologies. This module effectively dissipates heat, ensuring stable operation even under demanding conditions. The IQSMX-6 supports a wide input voltage range, making it adaptable for different applications, from consumer electronics to industrial machinery.

In contrast, the IQAMB-5 focuses on advanced analytics and monitoring capabilities. This model utilizes sophisticated algorithms for real-time data processing, allowing users to monitor system performance metrics and identify potential issues before they escalate. The architecture of the IQAMB-5 includes an intuitive user interface that simplifies operation, making it accessible for both skilled technicians and those new to the technology. Additionally, it features robust communication protocols, ensuring seamless integration with existing systems for enhanced interoperability.

Both models leverage Crown's proprietary technology, which includes energy-saving techniques that not only boost efficiency but also contribute to reducing operational costs. Their design emphasizes sustainability, catering to industries seeking environmentally responsible solutions. Furthermore, the compact form factor of the IQSMX-6 and IQAMB-5 enables easy installation in constrained spaces, providing versatility in deployment.

Security is another focal point for both devices. They incorporate advanced cybersecurity measures to protect data integrity and user privacy. This function is vital in today's digital landscape, where threats are ever-evolving, and organizations require reliable systems that prioritize safety.

Overall, the Crown IQSMX-6 and IQAMB-5 stand out as leading-edge solutions that embody Crown's mission to innovate and advance technology. With their distinctive features, state-of-the-art technologies, and commitment to quality, these models are poised to cater to a wide range of industries and applications, helping organizations enhance their operational capabilities while striving for sustainability. Through continuous improvements and adaptability, these products represent the future of efficient, secure, and smart technology.