Crown IQSMX-6, IQAMB-5 Mixer/Multiplexer as a 1-Loop IQ Interface, Wiring the Crown Local Net

Page 28

AMB-5 /SMX-6IQ Mixer/Multiplexer

6.3The Mixer/Multiplexer as a 1-Loop IQ Interface

The mixer/multiplexer can serve a an IQ interface between a host computer and a single Crown Bus loop for other IQ–AMB-5/IQ–SMX-6 units only. This can eliminate the need for an external IQ Interface (IQ-INTII) in a small system. The mixer/multiplexer connects directly to the host computer via the DB9 serial connector. Switches accessed through the side of the chassis are used to select the parity and baud rate. See Section 3.2 for specific instructions on wiring and switch settings.

While 250 IQ components of each type can be con- trolled on a single Crown Bus loop, it is recom- mended that no more than 20 units be connected to an mixer/multiplexer. This is because of the tremen- dous timing demands on their microprocessors. More than 20 IQ components may cause timing problems.

6.4 Crown Local Net (IQ–SMX-6 only)

Crown Local Net (CLN) is available only for an IQ– SMX-6. It enables multiple IQ–SMX-6s to be inter- connected via a CLN. This is an RS232 communication loop designed for local communica- tion between IQ components apart from the Crown Bus. IQ–SMX-6s can use this option to communi- cate the total number of open mics in the system as well as their individual ducking priorities. In this way, one IQ–SMX-6 will know how many mics are being used by other IQ–SMX-6s and can take appropriate action to prevent feedback or implement priority switching (ducking) of mics.*

6.4.1 Wiring the Crown Local Net

A Crown Local Net is a serial loop (Figure 6.16). With two exceptions, a Crown Local Net loop is wired the same as standard RS232 wiring, except the Crown Local Net does not use handshaking therefore pins 7 and 8 (RTS/CTS) are not used.

Figure 6.17 shows the wiring for a 3-unit Crown Local Net. If more units are desired, simply add another unit and follow the same pattern for wiring.**

*Because Loop IQ Interface and CLN use the same DB9 connector, they cannot be used at the same time. This means that IQ–SMX-6s to be used in a CLN will need to be connected to a Crown Bus via an external IQ interface for setup.

**Pin 5 should not be used as a ground if the units are already properly grounded. The wire used for RS232 communication is usually unsuitable for use as a ground.

CLN Interface

CLN Interface

CLN Interface

RS232

RS232

RS232

Figure 6.16 A Crown Local Net RS232 Serial Loop

Important: The Crown Local Net must make a complete loop. If the last unit in a group is not connected to the first unit, the system will not function.

Important: The Crown Local Net depends on proper IQ address assignments, even if the sys- tem will not be installed with a Crown Bus loop. Each unit in a Crown Local Net must have a different IQ address. See Section 3.2 for details.

As more diverse IQ communications are needed, the Crown Local Net will be available to move infor- mation directly between IQ components without af- fecting the performance of a host computer.

Figure 6.17 Crown Local Net Wiring

Page 28

IQ–AMB-5 / IQ–SMX-6 Reference Manual

Image 28
Contents AMB-5/*SMX-6 Three Year Full Warranty Important Safety Instructions Exclamation Mark Symbol Lightning Bolt SymbolCrown Audio Technical Support Group Quick Install Procedure Contents Illustrations IQ Audio In DepthWelcome UnpackingControls, Connectors & Indicators IQ Mixer / Multiplexer Controls, Connectors & IndicatorsHardware Installation Connecting to a Host Computer StepConnecting to the Crown Bus Step Set the IQ Address SwitchSelecting the IQ Address and Communication Parameters PIN Connect the Audio Wiring Step Connect Auxiliary Devices StepOperation HardwareAutomatic Mixing Features Computerized Control and MonitoringDuck Priority Input CompressorGate Count Ambience IQ-AMB-5 onlyTechnical Information Crown Local Net IQ-SMX-6 onlyAudio Input SectionControl and Interface Section IQ-AMB-5 Block Diagram IQ-SMX-6 Block Diagram IQ Audio In Depth Closer Look at Audio Signal WiringInput Cable ShieldedTwin-lead IQ-AMB-5 Ambient Sensing InputStack Inputs Audio Output SectionCorrect way to wire stacked units is shown below Paralleling inputsUsing the AUX Port 15 Internal Auxiliary CircuitWiring the Crown Local Net Mixer/Multiplexer as a 1-Loop IQ InterfaceCloser Look at Crown Bus Wiring IQ Address Switch IQ Address TablesIQ Address Switch Settings from 126 to Crown Audio Customer Service Factory ServiceFactory Service Shipping Instructions Crown Factory Service Information

IQAMB-5, IQSMX-6 specifications

Crown IQSMX-6 and IQAMB-5 are revolutionary products designed for various applications in the electronic and automotive sectors, delivering high performance, reliability, and advanced features. These models showcase Crown's commitment to delivering cutting-edge solutions tailored for modern needs.

The Crown IQSMX-6 is a compact, high-efficiency power module equipped with a variety of features aimed at optimizing performance while minimizing energy consumption. One of its standout characteristics is the integration of advanced thermal management technologies. This module effectively dissipates heat, ensuring stable operation even under demanding conditions. The IQSMX-6 supports a wide input voltage range, making it adaptable for different applications, from consumer electronics to industrial machinery.

In contrast, the IQAMB-5 focuses on advanced analytics and monitoring capabilities. This model utilizes sophisticated algorithms for real-time data processing, allowing users to monitor system performance metrics and identify potential issues before they escalate. The architecture of the IQAMB-5 includes an intuitive user interface that simplifies operation, making it accessible for both skilled technicians and those new to the technology. Additionally, it features robust communication protocols, ensuring seamless integration with existing systems for enhanced interoperability.

Both models leverage Crown's proprietary technology, which includes energy-saving techniques that not only boost efficiency but also contribute to reducing operational costs. Their design emphasizes sustainability, catering to industries seeking environmentally responsible solutions. Furthermore, the compact form factor of the IQSMX-6 and IQAMB-5 enables easy installation in constrained spaces, providing versatility in deployment.

Security is another focal point for both devices. They incorporate advanced cybersecurity measures to protect data integrity and user privacy. This function is vital in today's digital landscape, where threats are ever-evolving, and organizations require reliable systems that prioritize safety.

Overall, the Crown IQSMX-6 and IQAMB-5 stand out as leading-edge solutions that embody Crown's mission to innovate and advance technology. With their distinctive features, state-of-the-art technologies, and commitment to quality, these models are poised to cater to a wide range of industries and applications, helping organizations enhance their operational capabilities while striving for sustainability. Through continuous improvements and adaptability, these products represent the future of efficient, secure, and smart technology.