Crown IQSMX-6, IQAMB-5 manual Contents

Page 6

AMB-5 /SMX-6IQ Mixer/Multiplexer

CONTENTS

 

Quick Install Procedure

5

1

Welcome

8

 

1.1

Unpacking

8

2 Controls, Connectors & Indicators

9

3

Hardware Installation

10

 

3.1

Connecting to a Host Computer

10

 

3.2

Connecting to the Crown Bus

11

 

 

3.2.1 Set the IQ Address Switch

11

 

 

3.2.2 Connect to the IQ System via the Crown Bus

12

 

3.3

Connect the Audio Wiring

14

 

3.6

Connect Auxiliary Devices

14

4

Operation

15

 

4.1

Hardware

15

 

 

4.1.1

IQ Address Switch

15

 

 

4.1.2

Baud Rate and Parity Switch

15

 

 

4.1.3

Enable Indicator

15

 

 

4.1.4

DATA Indicator

15

 

 

4.1.5

Main Audio Inputs

15

 

 

4.1.6

Sense Input

15

 

 

4.1.7

Main Audio Outputs

15

 

 

4.1.8

Bus Outputs

15

 

 

4.1.9

Stack Audio Inputs

15

 

 

4.1.10

Crown Bus Connector

16

 

 

4.1.11

Crown Bus Ground Connector

16

 

 

4.1.12

RS232 Serial Port

16

 

 

4.1.13

Sensing AUX Port

16

4.2Computerized Control and Monitoring

4.2.1

Manual/Auto Mode

16

4.2.2

Input Level Monitors

16

4.2.3

Output Level Monitors

16

4.2.4

Bus Output Relays

16

4.2.5

VCA Gain Controls

16

Automatic Mixing Features

 

4.2.6

Gate

16

4.2.7

Duck Priority

17

4.2.8

Input Compressor

17

4.2.9

Auto Level

17

4.2.10

Output Compressor

18

4.2.11

Gate Count

18

4.2.12 Ambience

18

4.3 Crown Local Net

19

5 Technical Information

19

5.1Audio 19

5.1.1

Input Section

19

5.1.2

VCA Sections

19

5.1.3

Output Section

20

5.1.4

Level Sense Circuits

20

5.2 Control and Interface Section

20

5.2.1

Crown Bus Interface

20

5.2.2

RS232 Interface

20

5.2.3

D/A Converter

20

5.2.4 Log Amp and A/D Converter

20

Page 6

 

IQ–AMB-5 / IQ–SMX-6 Reference Manual

Image 6
Contents AMB-5/*SMX-6 Three Year Full Warranty Important Safety Instructions Lightning Bolt Symbol Exclamation Mark SymbolCrown Audio Technical Support Group Quick Install Procedure Contents Illustrations IQ Audio In DepthWelcome UnpackingControls, Connectors & Indicators IQ Mixer / Multiplexer Controls, Connectors & IndicatorsHardware Installation Connecting to a Host Computer StepConnecting to the Crown Bus Step Set the IQ Address SwitchSelecting the IQ Address and Communication Parameters PIN Connect the Audio Wiring Step Connect Auxiliary Devices StepOperation HardwareAutomatic Mixing Features Computerized Control and MonitoringDuck Priority Input CompressorGate Count Ambience IQ-AMB-5 onlyAudio Technical InformationCrown Local Net IQ-SMX-6 only Input SectionControl and Interface Section IQ-AMB-5 Block Diagram IQ-SMX-6 Block Diagram Closer Look at Audio Signal Wiring IQ Audio In DepthInput Twin-lead CableShielded IQ-AMB-5 Ambient Sensing InputStack Inputs Audio Output SectionCorrect way to wire stacked units is shown below Paralleling inputsUsing the AUX Port 15 Internal Auxiliary CircuitWiring the Crown Local Net Mixer/Multiplexer as a 1-Loop IQ InterfaceCloser Look at Crown Bus Wiring IQ Address Switch IQ Address TablesIQ Address Switch Settings from 126 to Factory Service Crown Audio Customer ServiceFactory Service Shipping Instructions Crown Factory Service Information

IQAMB-5, IQSMX-6 specifications

Crown IQSMX-6 and IQAMB-5 are revolutionary products designed for various applications in the electronic and automotive sectors, delivering high performance, reliability, and advanced features. These models showcase Crown's commitment to delivering cutting-edge solutions tailored for modern needs.

The Crown IQSMX-6 is a compact, high-efficiency power module equipped with a variety of features aimed at optimizing performance while minimizing energy consumption. One of its standout characteristics is the integration of advanced thermal management technologies. This module effectively dissipates heat, ensuring stable operation even under demanding conditions. The IQSMX-6 supports a wide input voltage range, making it adaptable for different applications, from consumer electronics to industrial machinery.

In contrast, the IQAMB-5 focuses on advanced analytics and monitoring capabilities. This model utilizes sophisticated algorithms for real-time data processing, allowing users to monitor system performance metrics and identify potential issues before they escalate. The architecture of the IQAMB-5 includes an intuitive user interface that simplifies operation, making it accessible for both skilled technicians and those new to the technology. Additionally, it features robust communication protocols, ensuring seamless integration with existing systems for enhanced interoperability.

Both models leverage Crown's proprietary technology, which includes energy-saving techniques that not only boost efficiency but also contribute to reducing operational costs. Their design emphasizes sustainability, catering to industries seeking environmentally responsible solutions. Furthermore, the compact form factor of the IQSMX-6 and IQAMB-5 enables easy installation in constrained spaces, providing versatility in deployment.

Security is another focal point for both devices. They incorporate advanced cybersecurity measures to protect data integrity and user privacy. This function is vital in today's digital landscape, where threats are ever-evolving, and organizations require reliable systems that prioritize safety.

Overall, the Crown IQSMX-6 and IQAMB-5 stand out as leading-edge solutions that embody Crown's mission to innovate and advance technology. With their distinctive features, state-of-the-art technologies, and commitment to quality, these models are poised to cater to a wide range of industries and applications, helping organizations enhance their operational capabilities while striving for sustainability. Through continuous improvements and adaptability, these products represent the future of efficient, secure, and smart technology.