SET TEMPERATURE

This menu has the following parameters:

SET BOILER TEMPERATURE

Setting the boiler temperature.

TIME OVERHEATING BOILER

If the machine hasn’t worked for a long time, the boiler will overheat.

SET OVERHEATING BOILER

Boiler overheating value (max. 5°C).

TIME FILLING UP BOILER

The pump refills the boiler to keep the maximum level at the set time

SET FILLING UP BOILER

Boiler refilling time.

OPTIONS

This menu has 2 different levels that are protected by a password:

1st level. Operator - addressed to the machine operator

2nd level. Manager - addressed to the machine technician / manager

The machine has 3 working types that have their own selections and amounts counter:

standard:standard working with priced selections

test :working with priced selections and with the money that doesn’t go into the coin box (example: the technician has to test the machine and the payment system).

Free test:working with free selections.

The counters of every level are independent; therefore the zero resetting of the counters of a level doesn't influence the other counters

OPTIONS: LEVEL 1 (operator)

After you have inserted the correct password, which initially is “111”, the follow- ing menu will appear:

MODIFY PASSWORD LEVEL 1: Insert the new password and press E to con- firm it.

TEST MACHINE MODE: Set the machine in test mode working.

FREE MODE: Set the machine in free mode working.

SINGLE DRINK COUNTERS&AMOUNTS: Choose the id drink to analyse with + or - and press Enter to confirm.

REGULAR COUNTERS: standard working counter.

TEST MODE COUNTERS&AMOUNTS: Test mode working counter.

FREE MODE COUNTERS&AMOUNTS: Free mode working counter.

RESET COUNTERS&AMOUNTS: Above counters zero resetting: Press "6" to reset or "5" to cancel.

Pag. 16

Pag. 17

Image 16
Contents P180 Technical Features Grinder Installation Hydraulic Diagram Hydraulic ConnectionElectric Diagram Legend LoadingElectric Diagram WIRES’ Color LegendTroubleshooting Guide Switching onProgramming Frequent Menu Quick Functions∙ SET Drinks ∙ SET Prices ∙ Counters & Amounts ∙ Events SET Drinks 03-04-05-0 Sel.3SET Prices SOL.4 LIOF.SUG.VTest Mode Total COUNTERS&AMOUNTS Free Mode COUNTERS&AMOUNTSReset COUNTERS? Counters & AmountsEvents Electrical OutputSET Temperature Options Insert PasswordMain Menu Payment SystemPayment System SET Temperature Options