INSTALLATION
Before installing the machine, read carefully the manual.
The installation site must be level and dry.
ELECTRIC CONNECTION
Before connecting the machine to an electric plug, please follow these precau- tions:
oThe main supply must be suitable for the machine power requirements
(1600W).
oCheck that the power supply voltage is the same as the one shown in the
rating label.
oCheck that the main socket is correctly earthed.
oIf the power supply cable is to be replaced, use only original cables.
The manufacturer will not accept responsibility for any damage claiming if these precautions are not complied with.
The machine is provided with a general lighted switch, located on the back panel, and with a security push button on the chassis that will cut off the power to the electronic board when you open the door.
If you want to restore the power when the door is open, take out the push button.
All the machine electric devices work with a 24 VDC voltage, except for boiler heating element and the transformer that work with 230 or 115 VAC.
LEGEND
F | WATER FILTER |
VA |
DLIMESTONE FILTER (OPTIONAL) CV FLOWMETER
P PUMP
VVALVOLA NON RITORNO
C BOILER
EV1 TEA ELECTROVALVE
EV2 | MILK & CHOCOLATE ELECTROVALVE |
EV3 | NOT AVAILABLE |
EVE | ESPRESSO ELECTROVALVE |
GE | ESPRESSO BREWER |
M1 | TEA MIXING GROUP |
M2 | MILK & CHOCOLATE MIXING GROUP |
S | WASTE |
U1 | TEA OUTLET |
U2 | MILK & CHOCOLATE OUTLET |
U3 | NOT AVAILABLE |
UC | ESPRESSO OUTLET |
Pag. 4 | Pag. 29 |