Henkel K-900, K-1000 manual Safety Precautions, Operation, Save These Safety Instructions

Page 4

Safety Precautions

Read all instructions completely before attempting to operate this unit.

*** SAVE THESE SAFETY INSTRUCTIONS ***

To reduce the risk of electrical shock, fire, or personal injury follow the guidelines below:

Before connecting unit to a power source, be sure the voltage supplied is the same as that specified on the name plate of the unit.

Check outlet to ensure proper grounding of the electrical cable. Have a licensed electrician check the A/C power outlet if you are not sure.

Use this unit for its intended purpose as described by literature.

Make sure power cord is located so that it will not be stepped on, tripped over, or otherwise subjected to stress of heat, oil, or sharp edges. Do not close doors on the cord.

To reduce the risk of damage to the electric plug and cord, disconnect by plug rather than by the cord.

Do not use this unit if cord or plug is in poor condition. If it has been exposed to weather or immersed in water, have a qualified serviceman inspect and replace parts as necessary.

WARNING! NEVER HANDLE PLUG, CORD, OR UNIT WITH WET HANDS OR WHILE STANDING IN WATER.

Use special care when moving heavily loaded units.

Do not store combustible material on or around the unit.

Do not operate this unit empty.

When using the unit at a distance where an extension cord becomes necessary, a 3-conductor grounding cord of adequate size must be used for safety, and to prevent loss of power and overheating. Use only a UL listed extension cord suitable for outdoor use. Make certain wire size is large enough for A/C amperage rating of unit.

Operation

Load oven with desired amount of electrodes. To turn on the unit, simply plug the power cord into appropriate single phase A/C source and adjust thermostat to desired setting. (Check name plate for voltage.)

The ovens are supplies with a 6’ UL listed type S.J. cord. However, due to the many different recepticle configurations in the field a plug is not supplied. When attaching plug to power cord, be sure the plug is an approved component and is rated for the proper voltage and amperage.

All units meet electrical code requirements when used with a grounding plug and a grounded receptical.

Image 4
Contents HENKEL, INC P.O. BOX HAMMOND, LA Installation Instructions & Repair Parts List One Year Limited WarrantyHenkel, Inc Models K-900& K-1000Holding OvensK-900SPECIFICATIONS K-1000SPECIFICATIONSOperation Safety PrecautionsSAVE THESE SAFETY INSTRUCTIONS Troubleshooting Temperature SettingScheduled Maintenance VentingCorrective Maintenance THERMOSTAT CALIBRATION & ADJUSTMENTIF OVEN FAILS TO OPERATE - NO HEAT IF OVEN OVERHEATSWiring Diagrams K-900& K-1000Ovens CHANGING THE THERMOSTAT120Volts/3000 Watts 240Volts/3000 Watts480Volts/3000 Watts 480Volts 3 PhaseGrounding Plug 480 V/20A NEMA L8-20PNot Provided Model K-900& K-1000Repair Parts List K-900& K-1000W/T ACCESSORIES LISTHENKEL, INC Flux and Electrode Stabilizing GuideQuality Since Phone 985 Fax 985 PO Box Hammond, Louisiana