Henkel K-1000, K-900 manual Troubleshooting, Temperature Setting, Venting, Guide to Storage

Page 5

Temperature Setting

The thermostat is adjustable from 150°F (37.8°C) to 550°F (287.8°C). Turn thermostat knob to desired temperature by aligning with red line on chrome bezel. Pilot light indicates when power supply is supplied to the heating elements. The thermostat is accurate to ±25°F (14°C) a the sensor. Temperature variance is minimal throughout the oven due to the heat exchanging qualities of the Keen shelving system.

***CAUTION: DO NOT USE ON D/C POWER SUPPLY! ***

Venting

The models K-900 and the K-1000 ovens are vented through two screen plugs at the rear of the oven.

***CAUTION: SURFACE TEMPERATURE OF HEATING ELEMENTS WILL EXCEED 550°F. ELECTRODES ADVERSELY AFFECTED BY HIGH HEAT SHOULD BE STORED ON UPPER

SHELVES OF OVEN. ***

Guide to Storage

See the enclosed guide to storage. This guide may be used in the absence of storage information from the electrode manufacturer. In critical situations, contact your electrode manufacturer.

Functional Description

These models are designed to hold large amounts of electrodes at moderate optimum temperatures providing protection from harmful moisture. The unique diagonal shelf design allows the storage of 50lb. electrode containers eliminating the need to remove rods from containers. The individual shelf compartments also facilitate the storage of different type rods in the same oven without disorder.

Scheduled Maintenance

The manufacturer recommends that the unit be unloaded and cleaned of debris and dust every six months. It is also recommended that a temperature probe be placed inside the unit and the thermostat calibration checked at this time.

Troubleshooting

The Keen oven models K-900 and K-1000 require a minimal amount

of electrical knowledge to repair if necessary.

Image 5
Contents HENKEL, INC P.O. BOX HAMMOND, LA One Year Limited Warranty Installation Instructions & Repair Parts ListHenkel, Inc Models K-900& K-1000Holding OvensK-1000SPECIFICATIONS K-900SPECIFICATIONSSAVE THESE SAFETY INSTRUCTIONS Safety PrecautionsOperation Temperature Setting TroubleshootingScheduled Maintenance VentingTHERMOSTAT CALIBRATION & ADJUSTMENT Corrective MaintenanceIF OVEN FAILS TO OPERATE - NO HEAT IF OVEN OVERHEATSCHANGING THE THERMOSTAT Wiring Diagrams K-900& K-1000Ovens120Volts/3000 Watts 240Volts/3000 WattsGrounding Plug 480 V/20A NEMA L8-20PNot Provided 480Volts 3 Phase480Volts/3000 Watts K-900& K-1000W/T ACCESSORIES LIST Model K-900& K-1000Repair Parts ListFlux and Electrode Stabilizing Guide HENKEL, INCQuality Since Phone 985 Fax 985 PO Box Hammond, Louisiana