Roland S-OPT owner manual Turning the Power On and Off

Page 8

Turning the Power On and Off

This device has no power switch.

Power is switched on by plugging the power cord into a power outlet; remove the plug from the outlet to switch power off. When powering up, first connect any peripheral devices, then plug in the power to the S-OPT before turning on the power to the connected devices.

To prevent malfunction and/or damage to speakers or other devices, always turn down the volume, and turn off the power on all devices before making any connections.

Once the connections have been completed, turn on power to your various devices in the order specified. By turning on devices in the wrong order, you risk causing malfunction and/or damage to speakers and other devices.

Be sure to use the included power cord when connecting to the power supply.

There are two ways to input a power supply to this device: “AC IN” and “POWER LINK.”By connecting two S- OPT units using a proprietary POWER LINK cable (ARC-15, sold separately), power can be supplied to both S-OPT units from a single unit. By doing so, if the power supplied to the AC IN of one unit is interrupted, both S-OPT units can continued to be used. In addition to circuit redundancy using the S-4000 series REAC MAIN and BACKUP, the power supply can also be backed up.

Backing up the power supply (when connecting 2 S-OPT units with POWER LINK)

• When there is no external backup power supply, such as a UPS

Connect each “AC IN” of two S-OPT units to a normal outlet.

(Although both S-OPT units will operate if one of the two S-OPT units has power supplied to its “AC IN,” it is recommended that power be connected and supplied to AC IN of both units to improve system reliability.)

When there is an external backup power supply separate from the normal power supply, such as UPS

Connect “AC IN” of one S-OPT unit to the normal outlet, and connect the “AC IN” of the other S-OPT unit to the external backup power supply.

To completely shut off the power to the unit, disconnect the power cords from the “AC IN” sockets of the both units.

UPS:

Uninterruptible Power Supply

8

Image 8
Contents Main Specifications Copyright 2007 Roland CorporationImportant Safety Instructions Using the Unit Safely Using the Unit Safely Power Supply PlacementMaintenance Additional PrecautionsPanel Descriptions Front PanelPower Link Cable Clamp Power Link ConnectorRear Panel Grounding TerminalTurning the Power On and Off Connect each AC in of two S-OPT units to a normal outletHow to Use the Power Cord Clamps Using the Power Link Cable ClampAbout Placement Using the Unit While Mounted in a RackUsing the Reac Connector Cover Attaching the Rubber FeetUse and Handling of Reac Systems About Reac CablesUnderstanding Cables and Connections Cat5e Ethernet Cable TypesEthernet Connectors Cat5e Crossover Wiring Reac cable SC-W100SCat5e Straight-Through Wiring Installing the Ferrite Core on Ethernet Cables System Connection Example OPTSystem Connection Example Specifications OPT Reac Optical ConverterFor EU Countries Information Europe