S4TEF10xx-10x
Technical Specifications
For use with Transition Networks Model
Standards | G.703, AMI/B8Zs/HDB3 |
|
Data Rate | Fiber: 100 Mb/s |
|
Dimensions | 3.7" x 4.7" x 1.8" (93 mm x 120 mm x 47 mm) | |
Weight | 1 lb. (0.45 kg) (approximate) | |
Power Consumption | 6.0 watts |
|
Power Supply | 12 VDC, 0.8 Amp (North. Am., EU, Latin Am., Japan) | |
| 12 VDC, 1.25 Amp (UK, Australia, N.Z., South Africa) | |
| (The external power supply provided with this product | |
| is UL listed by the power supplier’s manufacturer.) | |
Environment | Tmra*: | 0 to 50°C (32 to 122°F ) |
| Storage Temperature: | |
| Humidity: | 5 to 95%, non condensing |
| Altitude: | to 10,000 feet |
Warranty | Lifetime |
|
*Manufacturer’s rated ambient temperature.
The information contained in this user’s guide is subject to change. For the most
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR, Subchapter J applicable at the date of manufacture.
CAUTION: Visible and invisible laser radiation when open. Do not stare into beam or view directly with optical instruments.
CAUTION: Use of controls, adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure.
Optional Accessories
The following items are available from Transition Networks
Part Number | Description |
|
| ||
| Output: 12.6VDC, 1.0 A |
|
|
| |
WMBL | Optional Wall Mount Bracket; 4.0 in. (102 mm) | |
|
|
|
WMBV | Optional Vertical Mount Bracket; 5.0 in. | (127 mm) |
|
|
|
WMBD | Optional DIN Rail Mount Bracket; 5.0 in. | (127 mm) |
Troubleshooting
If the media converter fails, isolate and correct the failure by determining the answers to the following questions and then taking the indicated action:
1.Is the “PWR” LED illuminated?
NO
•Ensure that the power adapter is the proper type of voltage and cycle frequency for the outlet (See “Power Supply” on page 14.)
•Ensure the power adapter is properly installed in the media converter and in the grounded outlet.
•Contact Tech Support:
YES
•Proceed to step 2.
2.Is the “LKF” LED illuminated?
NO
•Check the fiber cables for proper connection.
•Verify that the TX and RX cables on the local media converter are connected to the RX and TX ports, respectively, on the remote media converter.
•Contact Tech Support:
YES
•Proceed to step 3.
3.Is the “LNK” LED on a T1/E1port (with a copper cable installed) illuminated?
NO
•Check the copper cable connected to that T1/E1 port for proper connection.
•Contact Tech Support:
YES
•Proceed to step 4.
4.Is the “AIS” LED on a T1/E1 port (with a copper cable installed) illuminated?
YES
•The device connected to the T1/E1 port has failed. Correct the device failure.
•Contact Tech Support:
NO
•Proceed to step 5.
14 | techsupport@transition.com | 15 |