Transition Networks C4TEF10XX-10X specifications Install the T1/E1 Cable, Install the Fiber Cable

Page 5

S4TEF10xx-10x

Installation -- Continued

Install the T1/E1 Cable

1.Locate or build ITU-compliant copper cable with straight-through RJ-48 connectors installed at both ends. (See page 13 for the proper cable specifications for your network application.)

2.Connect the RJ-48 connector at one end of the cable to one of the T1/E1 ports on the S4TEF10xx-10x media converter.

3.Connect the RJ-48 connector at the other end of the cable to the T1/E1 port on the other device.

Installation -- Continued

Install the Fiber Cable

1.

Locate or build ITU- compliant 100Base-FX fiber cable with male, two-

 

stranded TX to RX connectors installed at both ends.

2.

Connect the fiber cables to the local S4TEF10xx-10x media converter as

 

described:

 

• Connect the male TX cable connector to the female TX port.

 

• Connect the male RX cable connector to the female RX port.

3.

Connect the fiber cables to the remote S4TEF10xx-10x media converter

 

as described:

Dry-Contact Relay

All four T1/E1 ports are equipped with an

T1/E1 port

Connect the male TX cable connector to the female RX port.

Connect the male RX cable connector to the female TX port.

RJ-48 dry-contact relay. The relay closes if the power is lost or if any of the individual T1/E1/E1 links are lost. The operational rating on pins 3 and 6 are 0-30 VDC, 100 mA (maximum).

3

relay

6

RJ-48C connector

Connect the fiber cable to the local media converter as shown.

RX

Connect the fiber cable to the remote media converter as shown

RX

Install the RS-232 Data Cable (included)

1.Use the enclosed RS-232 data cable with a male, DIN 6-pin connector on one end and a DB-9 connector installed on the other end.

2.Connect the DIN 6-pin connector to the RS-232 port on the S4TEF10xx- 10x media converter.

3.Connect the DB-9 connector at the other end of the cable to the RS-232 port on a computer or other device that is used to collect and display data.

Connect the 6-pin DIN connector to the media converter as shown.

Connect the DB-9 connector to the computer

RS-232 data cable (enclosed)

TX

TX

8

24-Hour Technical Support: 1-800-260-1312International: 00-1-952-941-7600

techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.

9

Image 5
Contents Stand-Alone Media Converter Configuration Switches InstallationSwitch Set #1 T1/E1 Options Copper and Fiber PortsSwitch Set #2 Serial Options Hardware/Software Jumper Power the Media ConverterFiber Loop-Back To set the jumperInstall the Fiber Cable Install the T1/E1 CableInstall the RS-232 Data Cable included Dry-Contact RelayT1/E1 LEDs OperationFiber Network LEDs Remote Management FunctionFiber Cable Cable SpecificationsT1/E1 Cable RS-232 Cable includedTroubleshooting Technical SpecificationsOptional Accessories Is the PWR LED illuminated?Is data transfer failing on the fiber port? Is data transfer failing on one of the T1/E1 ports?Compliance Information Contact Us33307.C Trademark NoticeCopyright Restrictions