Prince Castle 630-ROM4 manual Safety Information

Page 2

Romar Pasta Cooker

630-ROM4

 

 

Safety Information

 

 

 

 

 

Important!

 

 

 

 

 

 

 

 

 

 

 

 

WARNING!

 

 

 

Prince Castle reserves the right to change specifications

 

 

 

 

 

and product design without notice. Such revisions do

 

Indicates information important to the proper operation of

 

 

 

 

 

 

 

not entitle the buyer to corresponding changes,

 

the unit. Failure to observe may result in damage to the

 

 

 

 

 

 

 

improvements, additions or replacements for previously

 

equipment and/or severe bodily injury or death.

 

 

 

 

 

 

 

purchased equipment.

 

 

 

 

 

 

 

 

 

CAUTION!

 

 

 

 

 

 

 

Indicates information important to the operation of the

 

 

 

 

 

 

 

unit. Failure to observe may result in damage to the

 

 

 

 

 

 

 

equipment.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Installation

 

 

 

 

 

 

 

 

 

 

Pre-Installation

 

 

 

 

 

General Setup

 

 

Pre-installation is the responsibility of the user and should be

 

 

 

This unit is completely pre-wired and thoroughly tested prior to

 

completed prior to the shipment of the unit to the location.

 

 

 

shipment. All wiring and hookups shall be done without

 

Floor drain sink located no further than 10 ft. from the

 

 

 

opening the unit.

 

 

 

 

 

 

 

 

 

intended location of the unit.

 

 

 

Place unit on the counter. The counter must be designed to fit

 

Electrical hookup box located no further than 5 ft. from the

 

 

 

 

the size and support the weight of the unit.

 

 

intended location of the unit. The box should provide three

 

 

 

The unit must be level to insure proper function. To level the

 

 

phase, 240 V protected with a three-phase 30-A breaker. All

 

 

 

 

 

 

 

 

 

unit, use only the adjustable leveling feet (no shims or foreign

 

 

terminals should be rated for gauge number 10-4 wire (L1-L2-

 

 

 

 

 

 

 

 

 

 

objects).

 

 

L3-Ground).

 

 

 

 

 

 

 

 

 

 

 

 

 

Dedicated water outlet with manual shut off valve no further

 

 

 

EPH require a minimum height of 4 in. between the counter

 

 

than 7 ft. from the intended location of the unit. The water

 

 

 

 

and the unit.

 

 

pressure should be at least 50 psi. The manual shut-off valve

 

 

 

 

 

 

 

 

output has to accommodate ¾ in. NPT Hose connector.

 

 

 

 

 

 

 

Supporting counter with the minimum suggested dimensions

 

 

 

 

 

 

 

 

of 24 in. high, 28 in. deep, and 44 in. wide. The counter must be

 

 

 

 

 

 

 

 

capable of withstanding 340 lbs (weight of unit).

 

 

 

 

 

 

 

 

 

 

 

 

 

Plumbing Connections

 

 

It is highly recommended that a licensed plumber install all

 

 

When connecting the steam generator blow-down outlet,

 

plumbing connections.

 

 

 

ensure that the valve (provided by Prince Castle) is reachable

 

All pre-installation and installation work must be in compliance

 

 

 

(arms length) from the front of the unit. The connecting “black

 

with national and local plumbing codes and health department

 

 

 

pipe” must be installed behind the unit and below the counter,

 

requirements.

 

 

 

away from easy reach. The blow-down piping must be

 

For standard water installation, connect per local plumbing

 

 

 

 

secured all the way to the floor sink.

 

 

 

Do NOT reduce the blow-down outlet from its original size.

 

 

codes.

 

 

 

The drainage from the unit to the floor sink is achieved by

 

 

 

 

 

 

 

 

 

 

 

 

 

gravity only. Make sure that the 1” white PVC tubing is directed

 

 

 

 

Depending on local regulations, you may be required to

 

 

 

downwards preventing any back-flow to the unit. Most local

 

 

 

 

install a second check valve or pressure reducing back-

 

 

 

Health Departments require you to terminate the drainage tube

 

 

 

 

flow preventive device.

 

 

 

4 in. above the highest point of the floor-sink.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Printed in USA 0404 © 2004

2

630-500

Image 2
Contents Romar Pasta Cooker 630-ROM4 Product IdentificationSafety Information Preparation of Pasta General Preparation & OperationElectrical Connections Before loading the pasta into the unit, the long-cutPasta Dispensers Trays & Strainers Switching the Unit OnPasta Guides/Funnels Buttons until the process is complete Sight GlassBlue I/O button blinks. Do not push any Daily Blow-Down Procedure Periodic Maintenance & CleaningDaily Maintenance Cooking PastaDaily or Weekly Clean-Up Funnel top view

630-ROM4 specifications

The Prince Castle 630-ROM4 is a versatile and innovative food holding cabinet designed primarily for restaurants and food service establishments that prioritize quality and efficiency. This unit is engineered to maintain optimal food temperatures while retaining moisture and flavor, ensuring that meals are served at their best, even during peak serving times.

One of the standout features of the 630-ROM4 is its advanced thermal transfer technology, which evenly distributes heat throughout the cabinet. This ensures that every item is kept at the desired temperature, minimizing hot or cold spots that can negatively impact food quality. The unit is equipped with a digital control system that allows operators to set precise temperature levels, providing flexibility for different types of food.

Additionally, the Prince Castle 630-ROM4 incorporates humidity control technology. By maintaining the right humidity levels, the cabinet helps prevent food from drying out, particularly important for items like baked goods and meats. This feature not only enhances the sensory attributes of the food but also extends its shelf life, reducing waste and contributing to overall cost savings.

The design of the 630-ROM4 is user-friendly, featuring a clear, easy-to-read digital display that shows real-time temperature and humidity levels. The cabinet is constructed from high-quality stainless steel, providing durability and ease of cleaning. The lightweight design facilitates movement and allows for flexible placement within a kitchen, making it suitable for both front-of-house and back-of-house use.

Furthermore, the unit is designed with energy efficiency in mind. It complies with the latest energy standards, helping businesses reduce their carbon footprint while keeping utility costs manageable. The Prince Castle 630-ROM4 is also built with safety features such as automatic shut-off and overheating protection, ensuring safe operation in busy food service environments.

In summary, the Prince Castle 630-ROM4 offers a robust solution for food holding and preservation. With its advanced thermal and humidity control technologies, user-friendly interface, and energy-efficient design, it stands out as an essential tool for any food service operation looking to enhance their meal quality and service efficiency. The combination of these features makes the 630-ROM4 a reliable choice for maintaining optimal food conditions while catering to the high demands of the restaurant industry.