Pitco Frialator PPE14-L, and RSE14 manual Safety Safety Safety Safety Safety

Page 4

SAFETY SAFETY SAFETY SAFETY SAFETY

WARNING

The cooker must be electrically grounded in accordance with local codes. If local codes do not apply, follow the requirements of National Code ANSI/NFPA 70-1990.

WARNING

This cooker is equipped with a three prong safety plug. This safety plug protects operators from electrical shock in the event of an equipment malfunc- tion. DO NOT remove the grounding (third) prong from this plug.

WARNING

Be sure the heating elements are COMPLETELY covered with water before turning the cooker on.

WARNING

The cooker must be disconnected from the facility power supply before servicing or cleaning the cooker.

WARNING

DANGER - HIGH VOLTAGE PRESENT

NEVER remove fuses from the cooker until the cooker is disconnected from the facility power supply.

SAFETY SAFETY SAFETY SAFETY SAFETY

Image 4
Contents Installation, Operation, and Maintenance Manual Page For Your Safety Safety Safety Safety Safety Safety Table of Contents Thermostat Calibration List of Tables Page General Information and Installation Inspecting Your NEW Cooker1 Leg/Caster Installation and Adjustment Assembly and LevelingBasket Lift Access Installation Clearances InstallationPlumbing Connections Electrical Connection Ventilation and Fire Fighting System Initial Adjustments InspectionVisual Checks Initial CleaningFilling the Pasta Cooker High Temperature Limit Switch Operating Instructions Filling the CookerCooker START-UP CookingDaily Cleaning Electric Power FailureCooker Shutdown Weekly Cleaning Page Thermostat Calibration Owner Maintenance and AdjustmentsChecking and Replacing Fuses Maintenance Basket Lift LubricationOperator Troubleshooting Page