Kenmore ULTRAFILTER 300 625.384720, ULTRAFILTER 500 Remote Location for Reverse Osmosis System

Page 17

- REMOTE LOCATION FOR REVERSE OSMOSIS SYSTEM -

REMOTE RO INSTALLATION (storage tank not shown)

Possible remote locations for the RO nearby the kitchen or bathroom sink include; (1) a basement area underneath the sink, and (2) an adjacent room or closet. Longer lengths of tubing (see parts list on page 19) and telephone cable extension (purchase locally*) may be needed.

You can run the drain tubing directly to one of several suitable open drain points, as shown below, bypas- sing the faucet airgap and p-trap drain. This type of drain is the preferred over the p-trap drain adapter.

Checkyourlocalcodes. Always be sure to provide an air gap between the end ofthe hose and the drain point.

*Telephone cable extension must consist of a male connector on one end and a female connector on the other to keep proper polarity. Polarity may be reversed if a coupler is used and monitor will not work.

Note: Tubing

colors as

telephone ¢_ble

suppiied with RO system,

(monitormodemonly

RO product

 

 

water faucet

J

 

 

_

blee tubin 9

17

Problems, Questions? Call 1-800-426-9345 Kenmore Water Line

Image 17
Contents Model no Owners ManualSafety Guides WarrantyFull Warranty Reverse Osmosis Drinking Water System As instructed on page 9 before using product waterWhat Your Reverse Osmosis System will do Table of ContentsBefore YOU Begin to Install the RO System Steps to Install Where to Install the RO SystemTools and Materials Needed StepWater Supply Install Cold Water Supply FittingWater Supply Fitting Install Faucet Install Drain AdapterWithout dips, loops, low spots or kinks Prepare Mounting HoleInstall RO Assembly InstallConnect Tubing to Faucet AS Follows Tubing from RO SystemConnect Drain TUBING, Faucet to Install Storage TANK, Make Remaining Tubing ConnectionsTypical Undersink Installation Pressure Testing SANITIZING, Pressure Testing & PurgingHOW Your Reverse Osmosis System Works Reverse Osmosis Water Flow Schematic Prefilter and Post Filter Cartridges Care of Your Reverse Osmosis SystemRO Membrane Cartridge Turn offthe water supply and open the RO faucetTubing Connection Flow ControlShutoff AssemblyChanging CoUet and O-ring FIG Reverse Osmosis System Care Guide Other Troubleshooting CausecorrectionDimensions and Specifications Remote Location for Reverse Osmosis System Remote RO Installation storage tank not shownRepair Parts @ not included Sears