Parasound owner manual Configuring the Zamp v.2 for Mono operation, Auto On Select Switch

Page 7

Configuring the Zamp v.2 for Mono operation

1.Turn the unit off.

2.Connect the single cable from your mono source to the Right channel Input jack.

3.Set the Stereo-Mono Switch to its Mono position.

4.Connect the positive lead of the speaker wire to the red R+ channel speaker terminal.

5.Connect the negative lead of the speaker wire to the red L+ channel speaker terminal. Note: the R+ and L+ terminals are not spaced to accept a dual banana plug.

Automatic Turn On Options

For automation and convenience, the Zamp v.2 can be turned on and off by applying a voltage to the Trigger In jack or by the presence of an audio signal at the input.

Auto On Select Switch

In the right position of the Auto On Switch, the Zamp v.2 is triggered on and off with an external +9 V to + 12 V voltage. When the external voltage ceases the Zamp v.2 will turn off immediately.

In the middle position of the Auto On Switch, the auto on function is disabled and the Zamp v.2 can only be turned on and off manually by the On-Off button on the front panel.

In the left position of the Auto On Switch, the Zamp v.2 is turned on and off when an audio signal is present at the Left and Right Input jacks. When the audio signal ceases, the Zamp v.2 will remain on for about five minutes. This prevents unwanted turn off during pauses in the music.

Trigger Input Connection

The Zamp v.2 can be triggered on with an external DC voltage source from +9 V to

+12 V. Many audio video controllers, and all Parasound audio video surround controllers produced since 1997, include trigger outputs for this task.

To activate the Zamp v.2 with an external voltage source, plug one end of the provided cord to the +12 V Trigger Input of the Zamp v.2 and the other end to the source component’s +12 V output. Parasound sources will have a matching 2.5mm jack, but if the source trigger is a terminal, you can cut off the plug at one end and attach the bare wires. The lead with the white stripe on it corresponds to the plug’s tip and the unmarked lead corresponds to the sleeve of the plug.

If the trigger voltage source is DC, the trigger plug tip must be positive and its sleeve negative. The trigger circuit is optically coupled and thus only draws 15 mA of current for activation.

7

Image 7
Contents Zamp v.2 Zone Amplifier Table of Contents Important Safety Instructions Zamp v.2 Front and Rear Panel Unpacking Looping Output Connections Connection PrecautionsStereo Mono Switch Input ConnectionsAuto On Select Switch Configuring the Zamp v.2 for Mono operationTrigger Input Connection Front Panel Indicators AC Line Audio Trigger Sensitivity AdjustmentGround Lift Switch AC Power Connections and AC GroundingHeadphone Jack Main Power FuseIf All Else Fails Parasound Staff Returning your Zamp to Parasound for ServiceImportant Notice before Shipping your Zamp Finally115 Slew Rate Continuous Power Output MonoWeight Current CapacityParasound Products, Inc. Rev