Agilent Technologies 6000 Series quick start This Book

Page 4

In This Book

This Programmer’s Quick Start Guide is your introduction to programming the oscilloscope using an instrument controller PC. This book and the Programmer’s Reference, which is supplied as a Microsoft Windows help file on CD, describes the 6000 Series oscilloscope’s programming interface.

This book contains the following information:

Chapter 1, “Setting Up”, describes the steps you must take before you can program the oscilloscope. It also describes how to access the Programmer’s Reference online help file.

Chapter 2, “Getting Started”, gives a general overview of oscilloscope program structure and shows how to program the oscilloscope using a few simple examples.

See Also

For in-depth information on oscilloscope commands, see the online Programmer’s Reference help file.

For more information on using the SICL, VISA, and VISA COM libraries in general, see the documentation that comes with the Agilent IO Libraries Suite.

For information on controller PC interface configuration, see the documentation for the interface card used (for example, the Agilent 82350A GPIB interface).

For information on oscilloscope operation, see the User’s Guide.

For detailed connectivity information, refer to the Agilent Technologies USB/LAN/GPIB Connectivity Guide, which you can download from the Agilent web site at the following URL: www.agilent.com/find/connectivity.

4

Agilent 6000 Series Oscilloscopes Programmer’s Quick Start Guide

Image 4
Contents Programmer’s Quick Start Guide WA R N I N G Programming the Oscilloscope-At a Glance This Book Contents Index Setting Up Install Agilent IO Libraries Suite software Connect and set up the oscilloscopeUsing the USB Device Interface Using the LAN InterfaceUsing the Gpib Interface Verify the oscilloscope connection Click Test Connection Setting Up To access the Programmer’s Reference help file Access the Programmer’s ReferenceTo get the latest versions via the web Getting Started Language for Program ExamplesBasic Oscilloscope Program Structure InitializingCapturing Data Analyzing Captured DataProgramming the Oscilloscope Referencing the IO LibraryOpening the Oscilloscope Connection via the IO Library Initializing the Interface and the Oscilloscope Using AUToscale to Automate Oscilloscope SetupInformation for Initializing the Instrument Using Other Oscilloscope Setup Commands Example Oscilloscope Setup CodeSet TIMebaseMODE to Main or DELayed when using DIGitize Capturing Data with the DIGitize CommandEnsure New Data is Collected Following program example shows a typical setup Aborting a Digitize Operation Over GpibReading Query Responses from the Oscilloscope Reading Query Results into String Variables Express String Variables Using Exact SyntaxReading Query Results into Numeric Variables Reading Definite-Length Block Query Response Data #8000010001000 bytes of dataterminatorSending Multiple Queries and Reading Results Checking Instrument StatusSending Scpi Commands using Browser Web Control Other Ways of Sending CommandsTelnet Sockets Index Index Page Index
Related manuals
Manual 368 pages 7.71 Kb

6000 Series specifications

Agilent Technologies has long been recognized as a leader in the field of electronic measurement and test equipment, and the Agilent 6000 Series oscilloscopes exemplify this commitment to innovation and quality. Designed for both professional engineers and researchers, the 6000 Series offers a comprehensive suite of features that enhance usability, accuracy, and efficiency in various applications.

At the heart of the Agilent 6000 Series is its advanced architecture, which integrates a high-performance analog-to-digital converter (ADC) and a sophisticated digital signal processing engine. This combination enables users to capture fast, high-resolution signals with remarkable accuracy, making it suitable for a wide range of applications, from automotive to telecommunications.

One of the standout features of the 6000 Series is its bandwidth options, which typically range from 100 MHz to 500 MHz. This flexibility allows users to select an oscilloscope that best fits their specific needs. Coupled with a sampling rate of up to 4 GSa/s, the 6000 Series offers exceptional timing resolution, ensuring that even the most fleeting signals are accurately represented.

The user interface of the 6000 Series is designed for maximum efficiency. The oscilloscopes are equipped with a large, high-resolution display, enabling users to view complex waveforms in detail. Furthermore, the touch screen interface provides a level of interactivity that simplifies navigation through various functions, making it accessible for both seasoned professionals and novices alike.

Additionally, the 6000 Series incorporates advanced triggering capabilities, allowing users to isolate specific events in their signals easily. The wide array of available triggering options includes edge, pulse width, and serial triggering formats, which are vital for analyzing complex digital communications.

Another noteworthy characteristic of the Agilent 6000 Series is its built-in measurement and analysis tools. The oscilloscopes come equipped with automated measurements, enabling users to quickly gather important data about their signals without manual calculations. This reduces the time spent on testing and increases overall productivity.

In terms of connectivity, the 6000 Series includes USB and LAN interfaces, providing easy data transfer and integration with other devices. The inclusion of advanced software options further enhances data analysis capabilities, enabling users to perform extensive post-acquisition analysis.

In summary, Agilent Technologies' 6000 Series oscilloscopes represent a blend of cutting-edge features, user-friendly design, and high-performance technologies, making them an invaluable tool for engineers and scientists engaged in electronic measurements and analysis. Their versatility and power make them well-suited to meet the demands of modern engineering challenges.