Weed Eater 545117523 instruction manual Double Insulation CONSTRUC- Tion, UNIT/MAINTENANCE Safety

Page 3

change the equipment plug, extension cord receptacle, or extension cord plug in any way.

DTo reduce the risk of electrical shock, use extension cords specifically marked as suitable for outdoor appliances. The electrical rating of the cord must be higher than the rating of the unit. The cord must be marked with the suffix “W-A” (in Cana- da, “W”). Make sure your extension cord is in good condition. Inspect extension cord before use and replace if damaged. An undersized extension cord will cause a drop in line voltage resulting in loss of power and overheating. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord. (NOTE: The correct size to be used de-

pending on the cord length is shown in this manual. See SELECT AND EXTEN- SION CORD in the ASSEMBLY section).

SDo not use multiple cords.

SKeep the extension cord clear of operator

and obstacles at all times.

D Tie cord to cord retainer and connect to recessed plug as shown in this manual to prevent damage to unit and/or extension cord and to reduce the possibility of the extension cord disconnecting from the unit during operation.

DDo not attempt to repair unit. Inspect the insulation and connectors on the unit and extension cord before each use. If there is any damage, do not use until damage is repaired by your authorized service

dealer.

DDon’t use the unit if the switch does not

turn the unit on and off properly. Have the unit repaired by an authorized service dealer.

D Avoid accidental starting. Be sure the switch is in the OFF position and keep your hand and fingers away from the switch while connecting the unit to the power source or when carrying a unit connected to the power source.

D Avoid any body contact with any grounded conductor, such as metal fences, or pipes, to avoid the possibility of electric shock.

D Ground Fault Circuit Interrupter (GFCI) protection should be provided on the cir- cuit or outlet to be used for this unit. Re- ceptacles are available having built-in GFCI protection and may be used for this measure of safety.

DStop the motor immediately if you are ap- proached.

3

DOUBLE INSULATION CONSTRUC- TION

Your unit is double insulated to help protect against electric shock. Double insulation construction consists of two separate “lay- ers” of electrical insulation instead of grounding. Tools and appliances built with a double insulation system are not intended to be grounded. No grounding means is provided on this unit, nor should a means for grounding be added to this unit. As a re- sult, the extension cord used with your unit can be plugged into any standard 120 volt electrical outlet.

Safety precautions must be observed when operating any electrical tool. The double in- sulation system only provides added pro- tection against injury resulting from an inter- nal electrical insulation failure.

WARNING:

All electrical repairs to this unit, including housing, switch, motor, etc., must be diag- nosed and repaired by an authorized ser- vice dealer. Replacement parts for a double insulated appliance must be identical to the parts they replace. A double insulated appliance is marked with the words

“DOUBLE INSULATION” or “DOUBLE INSU- LATED.” The symbol (square within a

square) may also be marked on the ap- pliance. Failure to have the unit repaired by an authorized service dealer can cause the double insulation construction to become ineffective and result in serious injury.

UNIT/MAINTENANCE SAFETY

DDo not set the unit on any surface except a clean, hard area while the unit is run- ning. Debris such as gravel, sand, dust, grass, etc., could be picked up by the air intake and thrown out through the dis- charge opening, damaging the unit, prop- erty, or causing serious injury to bystand-

ers or operator.

D Do not overreach or use from unstable surfaces such as ladders, trees, steep slopes, rooftops, etc. Use extra care when cleaning on stairways. Keep firm footing and balance at all times. Keeps hands out of tubes.

DInspect the entire unit before each use for worn, loose, missing, or damaged parts. Do not use until the unit is in proper work- ing order.

D This unit is double insulated. See the

DOUBLE INSULATION CONSTRUCTION

section. Have all internal service per- formed by qualified service repair person- nel to avoid creating a hazard or voiding your warranty.

Image 3
Contents English Español Français Manual de Instrucciones Manuel d’InstructionsSafety Rules Operator SafetyElectrical Safety Double Insulation CONSTRUC- Tion UNIT/MAINTENANCE SafetyStandards Blower SafetyAssembly Blower Assembly Attaching the Blower Tube and NozzleRemove the Inlet Restrictor Adjusting the Shoulder Strap on the Collection BAG HOW to Convert Unit from Vacuum USE to Blower USESelect AN Extension Cord ALL Other Models Using Your UnitUsing Your Unit AS a Blower Using Your Unit AS a VacuumMaintenance ServiceStorage Need ASSISTANCE? Limited Warranty