Sears 919.32721 owner manual Grounding the Generator, Installing Wheel KIT, Key No. Description

Page 9

IMPORTANT: Before any attempt to start your generator be sure to check engine oil (See OPERATION under Adding Engine Oil on page 12.)

GROUNDING THE GENERATOR

This generator should be grounded to help prevent accidental electrical shock. Shown below is a picture of the grounding lug supplied on your generator. First, drive a 3/4" or 1" diameter copper pipe or rod into the ground close to the generator set. The pipe must penetrate moist earth. Using #10 gauge wire, connect one end of the wire into the grounding lug. Next, connect the other end of the wire to the copper pipe or rod using an approved ground clamp.

• Insert the threaded stud of rubber foot (10) through the middle hole of the foot bracket (5). Secure with lock nut (8)and tighten.

Locate the support under the electrical outlet end of the generator. Position foot bracket (5), with rubber foot installed, under the support and align the holes in the foot bracket (5) with the slots in the support. Place one cap screw (9)through each slot in the support and the holes in the foot bracket. Secure with the lock nuts (8)and tighten.

Once completed, the wheel kit is ready for use.

This portability kit includes the following parts:

Grounding Lug

INSTALLING WHEEL KIT

The Sears Wheel Kit was designed to greatly improve the portablility of your generator. You will need (2) 1/2" wrenches and (2) 9/16" wrenches.

Place two 4"x4" pieces of wood on the floor. With

another person helping, carefully lift the generator and

place on top of the wood supports. This will support

the weight of the gasoline engine and generator while

the wheels, brackets, and handle are installed. Also, it

will allow access to the underside of the generator for

hardware installation. Fuel tank should be drained

prior to installation. Make sure that the generator is

supported evenly, level and will not fall.

Key

No. Description

1Wheel (2 used)

2Shoulder Bolt (2 used)

3Lock Nut 3/8"-16 (2 used)

4Wheel Bracket (2 used)

5Foot Bracket

6Handle

7 Handle Cap (2 used)

8Lock Nut 5/16"-18 (9 used)

9Cap Screw 5/16"-18 x 3/4"

(7 used)

10Isolator Foot

11Cap Screw 5/16-18 x 1.75" (2 used)

12Washer (2 used)

PART NO.

AC-0014

CAC-60 SSF-8111 -ZN GS-0561 GS-0562 GS-0564 GS-0565 SSF-8150

SS-12-CD

GS-0587

SSF-999-1 SS-6506-CD

• Place a handle cap (7) onto each end of handle prior

to installation.

• The handle should be installed on the electrical outlet

end of the generator. Place one washer (12) on long

cap screws (11). Align the handle brackets with the

upper holes pre-drilled in the generator frame. Place

mentioned screws through frame and handle brackets.

Secure with lock nuts (8) and tighten.

• Locate the engine support. Place one wheel bracket

(4) on top of support as shown in illustration below.

Align with the pre-drilled holes in support. Place 2 cap

screws (9) through holes in bracket and support.

Secure with 2 lock nuts (8) and tighten.

• Insert one shoulder bolt (2) into wheel (1). Insert

threaded end of bolt through wheel bracket, secure

with lock nut (3) and tighten. Note: The wheel will

not rub frame if installed properly.

• Repeat the above steps for the opposite side.

/

/

/

11

12

10

9 -- ENG

Image 9
Contents Owners Manual Table of Contents Hazard What could Happen HOW to Prevent IT Safety Guidelines DefinitionsRisk of Electrocution and Fire Informationfor preventingdamage toRisk of Electrocution and Fire contd Operate Unit Indoors or ANY Confined Area Risk of FireHazard Risk of Breathing Inhalation HazardRisk of Unsafe Operation Risk of HOT SurfacesRisk of Moving Parts Carton Contents Risk from LiftingRemove Generator from Carton Not rub frame if installed properly Installing Wheel KITGrounding the Generator Key No. DescriptionEngine RUN/STOP SWITCH- Sets engine in starting Know Your GeneratorVolt Twistlock RECEPTACLE- Used to Generator Capacity ReceptaclesObtaining Electricity from Generator Volts X Amp = WattsBefore Starting Engine Connecting Generator To Main Electrical SupplyAdding Engine Oil Low Oil ShutdownCustomer Responsibilities Connecting Electrical LoadsStopping The Engine Maintnenance TaskGenerator Maintenance Engine MaintenanceGeneral Recommendations Storage Instructions Problem Cause Correction KEY Frame AssemblyDescription Part Number Fuel TAN K Screws Fuel TankStator Assembly Rotor AssemblyTorque to 120-144-IN-LBS Torque to 30-40 IN-LBS Scale KEY Description Part Number Drive END AdapterGS-0207 SSF-595 SSF-584 SS-1525-CD KEY NO. Description281 \ RERNO. Partno REE no Partno Description RERNO. PARTNO. Description Manufacturers Emission Control System Warranty Coverage California & US EPA Emission Control Warranty StatementOwners Warranty Responsibilities Important NoteEMISSION-RELATED Parts Include the Following Emission Control System WarrantyHomeCentraF

919.32721 specifications

The Sears 919.32721 is a remarkable addition to the world of portable electronics, boasting a unique intersection of functionality, style, and technological advancement. Primarily recognized as a versatile multimeter, this device serves not only as a measurement tool for electricians but also appeals to hobbyists and professionals alike.

One of the main features of the Sears 919.32721 is its comprehensive measurement capabilities. It excels in measuring voltage, current, and resistance, making it an essential tool for diagnosing electrical issues in a variety of applications. The device offers both AC and DC voltage measurements, covering a broad range from household circuits to automotive systems. This feature enhances its usability, ensuring that the device can cater to different needs across multiple fields.

The design and user interface of the Sears 919.32721 are crafted with user experience in mind. It features a clear, easy-to-read LCD display that provides accurate readings in real-time, allowing users to make quick decisions during troubleshooting. The buttons are intuitively placed, providing easy navigation through various functions and settings, and the overall ergonomics of the device ensure comfort during prolonged use.

Technologically speaking, the multimeter is equipped with advanced circuitry that enhances measurement precision and stability. It employs true RMS technology, which allows the meter to deliver accurate readings even in the presence of non-sinusoidal waveforms, thus making it more reliable for various applications. Additionally, the Sears 919.32721 has built-in safety features such as overload protection, which safeguards the device from damage in the event of improper usage.

Portability is another defining characteristic of the Sears 919.32721. It is compact and lightweight, making it easy to carry around in toolboxes or pockets. This mobility facilitates on-site measurements, which is a significant advantage for technicians and engineers who work in diverse environments.

In conclusion, the Sears 919.32721 stands out in the market for its robust feature set and user-friendly design. It bridges the gap between technology and usability, making it an indispensable tool for anyone involved in electrical measurements and diagnostics. Whether for professional use or DIY projects, this multimeter delivers reliability and precision, ensuring that users can tackle any electrical task with confidence.