Numark Industries SA9500, SA3000, SA5500 owner manual Limiter On / Off Switch

Page 9

3.ensure that there is only one input signal connected to channel 1 of the amplifier - channel 2 input must be vacant

4. switch the amplifier to bridged mono (back panel switch)

5.turn the gain down and turn on the amp

6.verify operation at low gain, and then increase power to desired level, ensuring that the gain controls on each channel are set equally.

IMPORTANT: NEVER SWITCH BETWEEN STEREO AND BRIDGED MONO OPERATION WHEN THE AMPLIFIER POWER IS ON.

11. Limiter On / Off Switch

In cases where a dedicated compressor / limit unit precedes the SA5500, some users may seek to disable the on board limiting. Sliding the switch to the off position removes the limiting from both channels of the amplifier.

©1997 Numark Industries

9

http://www.numark.com

Image 9
Contents SA3000/SA5500/SA9500 Amplifiers Numark Industries Safety First Numark Industries Contents Introduction Front Panel Description Back Panel Description Limiter On / Off Switch Audio Terms Losses Due to Cable Runs OverloadBridged Mono Operation Hook up #1 Home Studio Reference Amplifier Hook up #3 Monitor Amplifier in bridged mono SA9500 SA5500 SA3000 SpecificationsBlock Diagrams Professional Disc Jockey Products