MOUNTING AND WIRING INSTRUCTIONS
CAUTION: For fixtures labeled for outdoor and wet location use, provide a
NOTE: Underwriters Laboratories (UL) does not require all fixtures to have ground wires. These fixtures meet all UL specifications.
1.Turn off power at circuit box to avoid possible electric shock.
2.Secure mounting bar (A) to outlet box (B) with outlet box screws (C) (not included) (see fig. 1).
3.Thread hex nut (D) onto mounting nipple (E) approximately 1/4 inch and insert lockwasher (F), then thread mounting nipple (E) onto mounting bar (A) and secure with hex nut (D).
4.Identify color coding of fixture wires (see fig. 2).
5.To connect wires, take black fixture wire (group A from fig. 2) and place evenly against black outlet box wire. Do not twist wires.
6.Fit wire connector (G from fig. 1) over wires and twist until there is a firm connection. If wire connector (G) easily comes off, reattach and check again for a firm connection.
7.Repeat steps 5 and 6 with the white (group B from fig. 2) fixture wires and outlet box wires.
8.Partially thread green grounding screw (H) into side hole (I) on mounting bar (A) (see fig. 1).
9.Wrap ground wire from fixture around green grounding screw (H), leaving enough excess wire to then connect ground wire and outlet box wire with wire connector (G), if applicable.
10.Tighten green grounding screw (H). Do not over tighten.
11.Tuckwires inside outlet box (B).
FIXTURE ASSEMBLY INSTRUCTIONS
1.Place back plate (J) over mounting bar (A), with mounting nipple (E) protruding through opening in back plate (J), and secure with cap nut (K).
2.Remove ball nuts (L) and bottom cover (M).
3.Install lamp(s). Do not exceed recommended wattage.
4.Replace bottom cover (M) and secure with ball nuts (L).
5.Turn power back on at circuit box.