Operation

Turn on the power and check operation of fan. The pull chain controls the fan speeds as follows:

1 pull - high; 2 pulls - medium; 3 pulls - low; 4 pulls - off.

Speed settings for warm or cool weather depend on factors such as room size, ceiling height, number of fans and so on.

The slide switch controls direction, forward or reverse.

Warm weather - (Forward) Fan turns counterclockwise direction. A downward air flow creates a cooling effect as shown in illustration A. This allows you to set your air conditioner on a higher temperature setting without affecting your comfort.

Cool weather - (Reverse) Fan turns clockwise direction. An upward airflow moves warm air off the ceiling area as shown in illustration B. This allows you to set your heating unit on a lower setting without affecting your comfort. (Please however refer to point 10 in Safety Tips when operating in this position.)

NOTE: Turn off and wait for fan to stop before changing the setting of the forward/reverse slide switch

Maintenance

1.Because of the fan’s natural movement, some connections may become loose. Check the support connections, brackets, and blade attachments twice a year. Make sure they are secure.

2.Clean your fan periodically to help maintain its new appearance over the years. Do not use water when cleaning. This could damage the motor, or the wood, or possibly cause electrical shock.

3.Use only a soft brush or lint-free cloth to avoid scratching the finish. The plating is sealed with a lacquer coating to minimize discoloration or tarnishing.

4.There is no need to oil your fan. The motor has permanently lubricated bearings.

Troubleshooting Guide

PROBLEM

Suggested Remedy

 

 

 

If fan does not start:

1.

Check main and branch circuit fuses or circuit breakers.

 

2.

Check wire connections as performed in step #14 of installation.

 

 

CAUTION: Make sure main power is turned off.

 

3.

Make sure forward/reverse switch is firmly to one side or the other. Fan will not operate

 

 

when switch is in the middle.

 

4.

If the fan still will not start, contact a qualified electrician. Do not attempt to troubleshoot

 

 

internal electrical connections yourself.

 

 

 

If fan sounds noisy:

1.

Check to make sure all screws in motor housing are snug (not over tightened).

 

2.

Check to make sure the screws which attach the fan blade holder to the motor are tight.

 

3.

Some fan motors are sensitive to signals from Solid State variable speed controls.

 

 

DO NOT USE a Solid State variable speed control.

 

4.

Allow “break-in” period of 24 hours. Most noises associated with a new fan will disappear

 

 

after this period.

 

 

 

If fan wobbles:

1.

Check that all blades are screwed firmly into blade holders.

 

2.

Check that all blade holders are tightened securely to motor.

 

3.

Make sure that canopy and mounting bracket are tightened securely to ceiling joist.

 

4.

If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can

 

 

redistribute the weight and possibly result in smoother operation.

 

 

If light does not work:

1. Check to see that the wire connections in the switch housing are connected.

 

2.

Check for faulty light bulbs.

 

3.

If light kit will still not operate, contact a qualified electrician for assistance.

 

 

 

14

 

UL-ES-XavierII-WH09

Image 14
Contents Xavier Iitm Peso NetoSafety tips / Consejos de seguridad Instalación con varilla vertical Aspas DE Doble CaraLista de piezas con letras de referencia G H Instalación Proceda Directamente a LA Página , Paso Normal Opción CONMÁS Larga UL-ES-XavierII-WH09 No está incluido el interruptor de pared Del dosel UL-ES-XavierII-WH09 Instale las bombillas FF de luz incluidas Para ventiladores con Control de pared AvisoPara ventiladores con Cadenilla de tiro Para ventiladores con Control remotoOperation Problema Solución Sugerida UL-ES-XavierII-WH09Titular de la licencia de Westinghouse Electric Corporation
Related manuals
Manual 24 pages 21.57 Kb

WH09 specifications

The Westinghouse WH09 is a compact and efficient portable air conditioner designed to provide cooling comfort for small to medium-sized rooms. Notable for its user-friendly features and advanced technologies, the WH09 stands out in the portable air conditioning market.

One of the main features of the Westinghouse WH09 is its cooling capacity, which is rated at 9,000 BTUs. This makes it ideal for rooms up to 300 square feet, such as bedrooms, living rooms, or home offices. With its powerful cooling capability, it effectively lowers ambient temperatures, ensuring a comfortable environment during hot summer days.

The WH09 utilizes a state-of-the-art inverter technology that enhances energy efficiency. Unlike traditional units that cycle on and off, inverter technology allows the compressor to adjust its speed according to the cooling demand. As a result, the Westinghouse WH09 consumes less energy while maintaining consistent cooling, ultimately leading to reduced utility bills.

Portability is another significant advantage of this air conditioner. The WH09 is equipped with caster wheels and integrated handles, making it easy to move from one room to another. The compact design allows it to fit comfortably in tight spaces without compromising performance. Furthermore, installation is straightforward, as it comes with a window kit that fits most standard windows, allowing for swift setup without the need for professional assistance.

In terms of usability, the Westinghouse WH09 includes a digital control panel and a remote control, allowing users to adjust settings conveniently from a distance. It features multiple fan speeds and cooling modes, including a dehumidification mode, making it suitable for various weather conditions. This versatility ensures optimal comfort, whether the goal is to cool, ventilate, or remove excess humidity from the air.

Moreover, the WH09 includes a washable filter, promoting better indoor air quality. Regular cleaning of the filter is essential to maintain efficient operation and prolong the unit’s lifespan, ensuring that users enjoy clean and fresh air throughout its use.

In summary, the Westinghouse WH09 portable air conditioner combines power, efficiency, and ease of use. Its impressive cooling capacity, energy-saving inverter technology, portability, and user-friendly features make it an excellent choice for individuals seeking comfort in smaller spaces. This unit not only enhances the living environment but also offers a convenient solution for beating the heat.