Westinghouse W-004 owner manual Mounting and Wiring Instructions, Fixture Assembly Instructions

Page 4

MOUNTING AND WIRING INSTRUCTIONS

CAUTION: For fixtures labeled for outdoor and wet location use, provide a water-tight seal between the fixture and the mounting surface by using silicone or similar caulking.

NOTE: Underwriters Laboratories (UL) does not require all fixtures to have ground wires. These fixtures meet all UL specifications.

1.Turn off power at circuit box to avoid possible electric shock.

2.Thread nipple (A) into center hole on mounting bar (B) approximately 3/4 inch (see fig. 1).

3.Secure lockwasher (C) and nut (D) to nipple (A) on back side of mounting bar (B).

4.Secure mounting bar (B) to outlet box (E) with outlet box screws (F) (not included).

5.Identify color coding of fixture wires (see figure 2 on page 11).

6.To connect wires, take black fixture wire (group A from fig. 2) and place evenly against black outlet box wire. Do not twist wires.

7.Fit wire connector (G from fig. 1) over wires and twist until there is a firm connection. If wire connector (G) easily comes off, reattach and check again for a firm connection (see fig. 1).

8.Repeat steps 6 and 7with the white (group B from fig. 2) fixture and outlet box wires.

9.Partially thread green grounding screw (H) into side hole (I) on mounting bar (B) (see fig. 1).

10.Wrap ground wire from fixture and ground wire (metal or green wire) from outlet box

(E) around green grounding screw (H) on mounting bar (B).

11.Tighten green grounding screw (H). Do not over tighten.

12.Tuckwires inside outlet box (E).

FIXTURE ASSEMBLY INSTRUCTIONS

1.Raise canopy (J) to ceiling with nipple (A) protruding through center hole of canopy (J) (see fig. 1).

2.Secure into place with washer (K) and cap nut (L).

3.Install lamp(s). Do not exceed recommended wattage.

4.Install square panel (M), textured sides facing outward, into bottom of fixture cage (N). (see figure 1).

5.Center four panel brackets (O) on each edge of square panel (M) (see fig. 1).

6.Insert side panels (P), textured side facing outward, behind interior corner slots (Q) of fixture cage (N).

NOTE: When side panels (P) are inserted into panel brackets (O), brackets will snap upward to secure panels into place. If needed, gently push side panels (P) down until brackets snap into place. After assembly, do not push on panels from the exterior of the fixture cage (N).

7.Raise fixture cage (N) to canopy (J), lining up holes in canopy (J) with holes in fixture cage (N), and secure with screws (R).

8.Turn power back on at circuit box.

4

Image 4
Contents Outdoor Lighting Fixture Installation Instructions Warranty Information Electrical Shock can Result in Serious InjuryLine art shown may not exactly match the fixture enclosed Mounting and Wiring Instructions Fixture Assembly InstructionsGarantie Limitée DE Cinq ANS Blocage C Instructions DE Montage ET DE Raccordement Instructions D’ASSEMBLAGE DE Lappareil DéclairageGarantía Limitada DE Cinco Años Advertencia UNA Descarga Eléctrica Podría Causar LesionesFigura Instrucciones DE Montaje Y Cableado Instrucciones DE Montaje DEL ArtefactoMise EN Garde Group aCleaning and Care Commande DE PiècesOrdering Parts Nettoyage ET Entretien

W-004 specifications

The Westinghouse W-004 is a next-generation nuclear power reactor designed to enhance energy production while prioritizing safety and efficiency. As part of the Westinghouse family of reactors, it integrates advanced technologies that meet the growing demands for reliable and sustainable energy sources.

One of the key features of the W-004 reactor is its pressurized water reactor (PWR) design, which utilizes water as both a coolant and a moderator. This configuration allows for efficient heat transfer while maintaining a stable reactor core. The W-004 is engineered to operate at a higher thermal efficiency compared to traditional reactors, resulting in lower operational costs and reduced emissions.

Safety is a paramount concern in nuclear reactor design, and the W-004 incorporates several innovative safety features. The reactor is equipped with a passive safety system that relies on natural forces, such as gravity and convection, to maintain cooling without the need for active mechanical systems. This design drastically lowers the risk of accidents and ensures that the reactor can safely shut down in case of emergency.

The W-004 also takes advantage of advanced digital instrumentation and control systems. These systems enhance monitoring and management of reactor operations with real-time data analytics, ensuring optimal performance and quick response times in emergency situations. The integration of digital technologies allows for better decision-making processes and greater operational flexibility.

In terms of fuel technology, the W-004 utilizes low-enriched uranium (LEU) fuel, which has been developed to maximize fuel efficiency and minimize waste. The reactor's design allows for longer refueling cycles, further increasing its operational efficiency and reducing downtime.

Moreover, the Westinghouse W-004 is designed to be modular, allowing for easier installation and scalability. This aspect makes it an attractive option for both new installations and upgrades to existing facilities, catering to a diverse range of energy needs.

With the global push toward cleaner energy, the Westinghouse W-004 stands out as a viable solution for sustainable electricity generation. Its state-of-the-art technologies, robust safety features, and impressive efficiency make it a significant player in the future of nuclear energy, embodying a balance between power production and environmental responsibility. As energy demands continue to rise, the W-004 can play an essential role in supporting a clean and sustainable energy future.