White Rodgers 1050 Burner Operation, Using diaphragm Gas Valve, Using Gas or, Solenoid Gas

Page 3

WIRING & OPERATION CONT.

All wiring should be done in accordance with local and national electrical codes and ordinances.

BURNER CONNECTIONS

Burner Operation

The indoor-outdoor control cycles the burner to vary boiler temperature to outdoor weather conditions.

INDOOR

 

DIAPHRAGM

OUTDOOR

 

 

GAS VALVE

CONTROL

 

 

 

 

 

THERM PILOT TRANS

Using diaphragm Gas Valve

TYPE 668 OIL

INDOOR

BURNER CONTROL

OUTDOOR

 

CONTROL

T

 

T

 

IGNITION

HIGH LIMIT

TRANS.

 

BURNER MOTOR

HOT

 

LINE

 

N

 

 

 

HOT

 

 

24V A.C.

LINE

 

 

 

N

 

 

TRANSFORMER

 

HIGH LIMIT

 

 

 

 

SAFETY

SAFETY

 

 

PILOT

 

 

PILOT

 

 

 

 

Using Gas or

 

LOW VOLTAGE

 

INDOOR

GAS VALVE OR

 

Solenoid Gas

 

SOLENOID GAS

 

OUTDOOR

 

Valve

VALVE

 

CONTROL

 

 

 

Using Oil burner control

HIGH LIMIT

HOT

LINE

 

24V A.C.

N

TRANSFORMER

CONNECTIONS TO CIRCULATOR

THERMOSTAT

Circulator Operation

1.Unzoned Systems, or Circulator-Zoned Systems — The thermostat cycles the circulator motor (through a relay) to meet the demand for heating.

2.System Zoned with Water Valves – Auxiliary contacts of water valves cycle circulator motor (through a relay) to meet the demand for heating. (The circulator runs as long as any zone is calling for heat.)

For Unzoned Sytems,

TYPE 809

or Systems Zoned

RELAY

 

 

 

With Circulators

 

 

 

1

2 L L

CIRCULATOR

MOTOR

FIELD INSTALLED JUMPER

HOT

LINE

N

 

4

 

4

 

4

 

4

 

4

6

5

6

5

6

5

6

5

6

5

TYPE 809 RELAY

For Systems Zoned

 

With Water Valves

2

2

5

4

2

2

5

4

2

2

5

4

6

 

1

3

6

 

1

3

6

 

1

3

 

 

 

HOT

ADDITIONAL

 

ZONES

 

LINE

 

 

 

N

 

 

 

 

2

2

5

4

2

2

5

4

6

 

1

3

6

 

1

3

TRANSFORMER

 

 

HOT

 

 

LINE

1

2 L

L

 

 

N

 

 

CIRCULATOR

 

 

MOTOR

3

Image 3
Contents Operator Save these instructions for future use Installation InstructionsPrecautions SpecificationsInstalling the Water Bulb InstallationWiring & Operation Installing the Outdoor BulbBurner Operation Using diaphragm Gas ValveUsing Gas or Using Oil burner controlAdditional Adjustments Dial SettingsSetting the Round Dial Setting the Square DialAdditional Information Chart 2 Round Dial Set 2 divisions Cooler than NChart 1 Round Dial Set at N Chart 3 Round Dial Set 4 divisions Warmer than NSpécifications Instructions D’INSTALLATIONRégulateur D’EAU Chaude INTÉRIEUR-EXTÉRIEUR Description PrécautionsCâblage ET Utilisation Installation DU Capteur ExtérieurInstallation DU Capteur Intérieur Installation DU Boitier DE CommandeCâblage ET Mode D’EMPLOI suite Ajustements Réglage DES Points DE ConsigneRéglage DU Cardran Rond Réglage DU Cadran CarréRéglage DES Points DE Consigne suite Renseignements SupplémentairesGraphique 1 Cadran rond réglé à N

1050 specifications

The White Rodgers 1050 is a programmable thermostat designed to optimize energy savings while providing exceptional comfort for homeowners. With its user-friendly interface and advanced features, it has become a popular choice in modern HVAC systems.

One of the standout features of the White Rodgers 1050 is its programmable capability, allowing users to schedule temperature adjustments based on their daily routine. This feature helps maintain an ideal environment while reducing energy consumption. The unit typically offers four programmable periods per day, giving users the flexibility to customize settings for different times, whether it's day, evening, or overnight.

Additionally, the White Rodgers 1050 is equipped with a large, clear display that is easy to read, even from a distance. This backlit screen enhances visibility, particularly in low-light conditions, making adjustments a breeze. The intuitive layout of the buttons simplifies navigation through the various settings, enabling users to change temperatures or modes with minimal effort.

The thermostat utilizes advanced technology to enhance its performance. One of its key features is the adaptive recovery mode, which learns how long it takes to heat or cool a space to the desired temperature. This ensures that the home reaches the preferred temperature at the scheduled time without wasting energy. Moreover, the 1050 includes an automatic changeover feature, allowing it to switch seamlessly between heating and cooling modes based on the home’s needs, thus providing year-round comfort.

Another significant characteristic of the White Rodgers 1050 is its compatibility with a wide range of heating and cooling systems, including gas, electric, heat pump, and multi-stage systems. This versatility makes it a suitable option for various HVAC setups.

For those concerned about energy usage, the White Rodgers 1050 provides energy usage reports and alerts, helping homeowners monitor their energy consumption patterns. This feedback can motivate more energy-efficient practices, ultimately leading to lower utility bills.

In conclusion, the White Rodgers 1050 thermostat blends advanced technology, user-friendly features, and energy-saving capabilities into a single, efficient device. Its programmable options, adaptive recovery feature, and compatibility with various systems make it a valuable addition to any home looking to optimize comfort and efficiency. Whether you are upgrading an existing system or installing a new one, the White Rodgers 1050 is poised to deliver the performance and convenience modern homeowners expect.