Solo USA 450, 444 manual Residual spray medium, Strainer for accessory sets

Page 14

Operating Hints

Wide-range nozzle (7):

Fig. 9

When spraying plants and trees we recommend fixing the wide-range nozzle (7) onto the red standard nozzle

(4). This ensures that a large area can be sprayed at one time. Push the wide-range nozzle onto the standard nozzle, until the bead engages.

In narrow spaces and for aftercare, we recommend placing the wide-angle grille (7a) onto the wide-range nozzle. This ensures that the spray velocity is reduced and the spray is applied more widespread, to prevent damage to leaves.

Nozzle attachment (6):

Fig. 10

The nozzle attachment (6) is positioned onto the standard nozzle (4) with the selected grille.

Use the dual grille (6a) when spraying cultures in rows (e.g. vines, tomatoes, nurseries), to achieve a good covering on the underside of the leaves.

The deflector grille can be replaced with a dual grille (6b). The dual grille provides a 90° - 110° spray pattern. The dual grille is usually used for spraying two rows at a time. The deflector grille and the dual grille can be placed onto the external diameter of the nozzle, until the bead engages.

ENGLISH 14

Dual nozzle (accessories, part no.: 49 00 137):

Fig. 11

Remove standard nozzle (4) from the spray wand and push the dual nozzle onto the spray wand.

7.4 Residual spray medium

Switch off the appliance as soon as no further liquid is expelled, when the metering body is correctly positioned for spraying, or air bubbles are visible inside the lance supply hose.

The tank will then contain less than 100 ml residual medium.

If you don’t want to refill the tank with spray medium and you want to terminate spraying, dilute the residual medium with 2 l of water. Dispose of this solution on the treated area.

7.5 Strainer for accessory sets

When using the liquid pump (accessory part no.: type 444 Î 44 00 114, type 450 Î 44 00 235) or the ULV accessory (part no.: 49 00 479), a strainer is integrated into the tank connector.

The strainer has a mesh size of 0.32 mm. Only use original strainer part no.: 25 00 198 with standard mesh size when replacing the strainer.

7.6 Checking the spray medium flow rate

At the beginning of the spraying season, check whether the equipment flow rate (l/min) still corresponds to the „Guide values“ table (see also item „Maintenance schedule“).

For this, fill the equipment up to the maximum marker with water, start using the equipment and spray for one minute exactly at maximum operating pressure. Then measure the water volume required to bring the water level back up to the maximum marker.

The actual volume measured represents the flow rate of the equipment in l/min at maximum operating pressure.

It should not deviate by more than 10 % from those listed in the „Guide values“ table. Should the actual value be too low, sediments inside the metering body may be the cause. Clean the corresponding parts and repeat the checking procedure.

Image 14
Contents 444 Parts subject to wear and tear SymbolsPreface Assembly GuaranteeImportant Components / Type plate Technical Specifications IndexImportant Components / Type plate TypeType Technical Specifications Mistblower 444 450Safety regulations Fuel-Information Maintenance and CareGeneral Maintenance Hints Spark Plug Carburettor adjustmentFollowing instructions are for authorised service shops Preparation for StorageAir Filter Maintenance Assembly of handle, spray tube and spray nozzle AssemblyAssembly of misting equipment Starting with warm engine after short stop Starting / Stopping the engineStarting with cold engine Shutting off engineFilling Adjustment of shoulder strapsOperating Hints Misting Output Guide TypeChecking the spray medium flow rate Strainer for accessory setsResidual spray medium Draining and cleaning the tank ApplicationMaintenance Plan Motorised sprayer accessories Made in Germany