Schneider Electric ION8800 manual Front of Meter Front Panel Sealing Point Cover Sealing Point

Page 33

Front of Meter

Front Panel Sealing Point

Cover Sealing Point

Front Panel Sealing Point

The meter incorporates sealing bars and chassis screws with through-holes, through which traditional lead/wire seals can be inserted. When utilized, these lead/wire seals effectively prevent unauthorized personnel from gaining access to meter internals or to buttons under the cover.

These seals are installed as follows:

1.Insert the sealing wire through both the screw hole and sealing bar.

Sealing Bar

Screw with

Through-hole

Sealing Wire

Lead Sealing Tab

2.Twist the wire and crimp the lead-sealing tab on to the wire.

© 2007 Schneider Electric. All rights reserved.

33

Image 33
Contents Energy & Power Quality Meter PowerLogic ION8800Page Installation Considerations Standards Compliance Network Compatibility Notice for the Internal ModemBefore You Begin ION8800 ModelsAvailable Options OptionsMeter Front Cover Closed Meter OverviewMeter Front Cover Open Meter BackFront Panel Button Functions Meter LabelsFront of Meter Cover Closed Removable User LabelsUnit Dimensions Side View of MeterFront of Rack View Essailec Connections Order Options B/C Circuit & Pinout DiagramsOrder Option a Circuit & Pinout Diagrams Meter Port Essailec Connector Pin Description Order Options A/B/C Essailec Connector ArrangementOrder Options D/E Circuit & Pinout Diagrams Order Options D/E Essailec Connector Arrangement Meter Battery ConsiderationsMount the Meter Installation Environmental Specifications IEC62052-11Form C Digital Output Mechanical Alarm Relay Wire the Digital I/OForm C Digital Output Solid State Relay Outputs DO1 DO4 Form a Digital Outputs Solid State Relay Outputs DO5 DO12Voltage Inputs Wire the Voltage and Current InputsCurrent Inputs High Current Option Current Inputs Low Current OptionWire Wye, 3-Element, 3 PTs Connection Diagram Wire Wye, 3-Element, Direct Connection DiagramWire Wye, 2½-Element, 2 PTs Connection L-N / 500 V L-L max. Volts Mode = 4W-WyeWire Delta, 2½-Element, Direct Connection Wire Solid-Grounded Wye, 3-Element, Direct ConnectionWire Delta, 2-Element 2 PTs & 2 CTs L-L max. Volts Mode = DeltaWire Delta, 2½-Element, 2 PTs & 3 CTs Single Phase Connection DiagramUsing Potential Transformers Wire Null modem RS-232 cable Wire the CommunicationsInfrared Connections COM1 RS-485 Connections COM2 and COM3Ethernet Connections optional module Ethernet TCP/IP Service PortsInternal Modem Connection COM4 optional module 10Base-TPower Up the Meter Wire the Power SupplySet Up the Meter Using the Front Panel Single Phase Power Supply4W-WYE Menu Setting Description Range Values Default SetupNetwork LD/LG, +/-, CAP/IND FormatDelta phasors for Unity Power Factor resistive load Phasor DiagramsApplicable Volts Mode = Delta Verify Meter OperationApplicable Volts Mode = 4W-WYE and 3W-WYE WYE 123 RotationWYE 132 Rotation Element 3Wire Delta 132 Rotation Element 3Wire Delta 123 RotationALT mode Norm modePer-phase voltage harmonic histograms Per-phase current harmonic histogramsMeter always returns to Norm mode after exiting Test mode Test ModeBattery Specifications Replacing the BatteryBattery Dimensions To replace the batteryHardware Locked Security Option Meter SecurityAnti-Tamper Sealing Methods Meter SealsFront of Meter Front Panel Sealing Point Cover Sealing Point Schneider Electric. All rights reserved Page Schneider Electric ION8800

ION8800 specifications

The Schneider Electric ION8800 is an advanced power monitoring and management device designed for commercial and industrial applications. It is engineered to enhance energy efficiency, reduce operational costs, and improve the reliability of electrical systems. As part of Schneider Electric's ION series, the ION8800 stands out due to its sophisticated metering capabilities and robust communication features.

One of the main features of the ION8800 is its high-accuracy power measurement. The device is capable of measuring a wide array of electrical parameters, including voltage, current, power, and energy consumption. With its accurate metering capabilities, operators can identify inefficiencies and optimize energy usage, thereby contributing to sustainability goals.

The ION8800 integrates with Schneider Electric's EcoStruxure™ platform, allowing seamless connectivity and data accessibility. This integration enables users to monitor their power systems remotely, gaining insights through real-time data visualization. Users can access detailed reports and analytics that help them to make informed decisions about energy management and equipment reliability.

In addition to its metering capabilities, the ION8800 incorporates advanced communication technologies. It supports multiple protocols, including Modbus, DNP3, and IEC 61850, ensuring compatibility with various industrial automation systems. This flexibility makes it suitable for integration in diverse applications and installations.

Another notable characteristic of the ION8800 is its scalability. The device can accommodate the growing needs of an organization, from single-entity monitoring to a larger network of devices. This scalability allows businesses to start with a basic setup and expand their monitoring capabilities as their energy management requirements evolve.

The ION8800 is designed to withstand harsh industrial environments, featuring durable construction and compliance with global standards. This resilience ensures reliability and longevity in various operational conditions. Additionally, the device’s user-friendly interface allows for easy configuration and operation, reducing the learning curve for new users.

Overall, the Schneider Electric ION8800 is a versatile and powerful tool for improving energy efficiency and management in commercial and industrial settings. Its advanced features, robust communication technologies, and scalability make it a valuable asset for businesses looking to enhance their energy monitoring capabilities. As companies increasingly focus on sustainability, the ION8800 provides the insights and tools necessary for effective energy management.