McIntosh MC207 owner manual Specifications

Page 22

Specifications

Specifications

Power Output

Minimum sine wave continuous average power output per channel, all channels operating is:

200 watts into a 4 ohm or 8 ohm load

Rated Power Band

20Hz to 20,000Hz

Total Harmonic Distortion

Maximum Total Harmonic Distortion at any power level from 250 milliwatts to rated power output is: 0.005% for 4 or 8 ohm loads

Dynamic Headroom 1.7dB

Frequency Response

+0, -0.25dB from 20Hz to 20,000Hz +0, -3dB from 10Hz to 100,000Hz

Sensitivity

1.0Volt Balanced with a 4 ohm Loudspeaker

2.0Volt Unbalanced with a 4 ohm Loudspeaker

1.4Volt Balanced with a 8 ohm Loudspeaker

2.8Volt Unbalanced with a 8 ohm Loudspeaker

A-Weighted Signal To Noise Ratio

89dB (112dB below rated output)

Intermodulation Distortion

Maximum Intermodulation Distortion if instanta- neous peak output per channel does not exceed twice the rated output, for any combination of fre- quencies from 20Hz to 20,000Hz, with all channels operating is:

0.005% for 4 or 8 ohm loads

Input Impedance

20,000 ohms Balanced

10,000 ohms Unbalanced

Wide Band Damping Factor

Greater than 60 at 4 ohms

Greater than 140 at 8 ohms

Power Requirements

100 Volts, 50/60Hz at 14.4 amps

110 Volts, 50/60Hz at 13.0 amps

120

Volts, 50/60Hz at 12.0 amps

220

Volts, 50/60Hz at

6.0 amps

230

Volts, 50/60Hz at

6.0 amps

240

Volts, 50/60Hz at

6.0 amps

Note: Refer to the rear panel of the MC207 for the correct voltage.

Overall Dimensions

17-1/2 inches (44.45cm) W, 9-7/16 inches (23.97cm) H, 18-3/4 inches (47.63cm) D, including clearance for con- nectors

Weight

83 pounds (37.6 kg) net, 116 pounds (52.6 kg) in shipping carton

22

Image 22
Contents Seven Channel Power Amplifier Important Safety Instructions Thank You Customer ServiceTable of Contents Please Take a MomentPerformance Features IntroductionDimensions Installation Rear Panel Connections and Switch How to Connect for Seven Channels How to Connect for Seven Channels How to Connect for Five Channels Twisted ends canHow to Connect for Five Channels How to Connect for Two Channels Zone B To AC Outlet Left Channel Zone B Right Channel Zone B Front Panel Displays and Controls Meter LightsPower On How to Operate and Read the Power Output MetersHow to Read the Power Output Meters Impedance SwitchTechnical Description Design PhilosophyBlock Diagram of the Amplifiers Protection Circuits Power Supply Circuits Technical Description, con’tPage Page Specifications Packing Instructions McIntosh Laboratory, Inc Chambers Street Binghamton, NY