GENERATOR FEATURES
Reference 1 - Air Cleaner. Refer to your Kohler engine manual for air cleaner care.
Reference 2 - Circuit Breakers. This portable single phase generator has 1 - 60 amp (A) thermal magnetic 2 pole breaker, 1 - 30 amp (A) thermal magnetic 2 pole breaker 1 - 30 amp (A) push to reset circuit breaker, and 2 - 20 amp (A) push to reset circuit breakers. Circuit breakers protect against electrical overloads.
Reference 3 - 120/240V Receptacle. This
receptacle is a 120/240V 60A NEMA
Reference 4 - 120/240V Twistlock Receptacle. This twistlock is a 120/240V 30A NEMA
receptacle. This receptacle accepts a NEMA plug number
Reference 5 - 120V Twistlock Receptacle. This twistlock is a 120V 30A NEMA
Reference 6 - 120V Receptacle. The generator has a control panel with two duplex (two receptacles in a common housing) receptacles. Each duplex is a 120 volt (V) 20 amp (A) straight blade receptacle, National Electrical Manufacturer’s Association (NEMA) number
ALWAYS use grounded male plugs. The neutral line of the generator is mechanically grounded to the frame. Matching NEMA male plugs must always be used.
WARNING Contact a licensed electrician to wire electrical plugs and/or cordsets. Improper wiring could result in a fire or electrical shock.
Reference 7 - Oil Drain Valve. Refer to your Kohler engine manual for oil change recommendations.
Reference 8 - Vibration Isolation Mounts. The engine and generator head are mounted on rubber cylinders that absorb most of the engine vibration. This feature eliminates the tendency of the machine to “walk” which is common in engine powered equipment.
Reference 9 - Starting/Stopping Instructions. Reference 10 - Wheel Kit. Heavy duty wheel kit
(Item # 165919).
Reference 11 - 10.0 Gallon Gas Tank. Large tank allows for extended run capabilities. Always allow room for gasoline expansion by not filling the gas tank completely full.
Reference 12 - Engine Key. The engine key switch is located on the front of the engine. Always locate this switch and be familiar with its location before operating the generator.
Reference 13 - Choke Lever. Used during cold starts. Refer to the starting/stopping instructions and the Kohler Command 25 engine manual for usage.
Reference 14 - Muffler and Spark Arrestor. Reference 15 - Oil Filter. Kohler oil filter number
Reference 16 - Battery Box and Battery. Battery is shipped without electrolyte. Fill each battery cell to the fill line with locally purchased electrolyte (sulfuric acid and water).
WARNING Sulfuric acid is a corrosive poison. Avoid contact with skin, eyes or clothing.
Reference 17 - Gas Line Valve. The generator tank has an
Reference 18 - Generator Head. The electricity producing part of the generator.
Reference 19 - Gas Drain Valve. The generator
is equipped with a unique feature. A gas drain valve is installed to drain gasoline from the tank without disconnecting the gas line feeding the engine. This valve is intended to be used to drain gas prior to extended periods of non use. It is recommended that if the period of non use is longer than 30 days, the gas should be drained, and the engine run until all the gas is evacuated from the carburetor. ALWAYS make sure this valve is closed prior to filling the gas tank.
Reference 20 - Gas Cap with Gauge. The gas cap is extra large, creating a large hole for refilling and a comfortable grip. You can always monitor the fuel level without removing the cap by using the fuel level indicator built into the gas cap.
Low Oil Shutdown. The Kohler engine is protected against damage resulting from low oil level. As the oil falls below the safe level, the engine automatically shuts off (the engine stop switch remains in the on position). The engine will not start until the oil is refilled to above the safe level.
INTRODUCTION
Before starting your generator, thoroughly study the instructions and cautions in this manual to assure you are fully acquainted with the operation of all components of this generator. Proper preparation, operation and maintenance will result in operator safety, best performance and long life of the generator. For detailed engine operation and maintenance always refer to the Kohler engine owner’s manual furnished with the generator.
North Star is constantly improving its products. The specifications outlined herein are subject to change without prior notice or obligation. The purchaser and/or user assumes liability of any modification and/or alterations on this equipment from original design and manufacture.
Before using, the user shall determine the suitability of this product for its intended use and assumes liability therein.